WARRANTY

You should first read all instructions before attempting to use this product.

For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp

2 years

Ballast

15 years

Electronic Components

1 year

A.  This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to 

damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered 

manufacturing defects under this warranty.

 

SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

 

Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so 

the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from 

jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B.  At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

C.  This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D.  This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: 

[email protected]

Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT 

TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING 

CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS

PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE

Toll-Free Phone #: 1-888-726-8869

Email: [email protected]

Website: www.sanuvox.com

Please be sure to specify product name.
Replacement parts for this product

BST120/277SHS

Ballast with input of 120 / 277VAC, 50 / 60Hz

LMPHGS120

12" UV straight lamp, germicidal only 

LMPHGS180

18" UV straight lamp, germicidal only 

LMPHGS240

24" UV straight lamp, germicidal only 

LMPHGS300

30" UV straight lamp, germicidal only 

LMPHGS400

40" UV straight lamp, germicidal only 

LMPHGS500

50" UV straight lamp, germicidal only 

LMPHGS600

60" UV straight lamp, germicidal only 

FLGFIXTUBE

Flange

MSCCON19

3/4 EMT connector

 WARNING

: Use only specified SANUVOX branded replacement UV lamps with your unit or system. 

Use of any other 

lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Содержание IL COIL CLEAN

Страница 1: ...d to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructio...

Страница 2: ...ion 5 Using the Coupler to Join Multiple 3 4 Support Rods 8 Step by Step Coupler Installation 8 OPERATION 9 How to Operate your Product 9 How to Read the LED Status Display 9 Dry Contacts for Building Automation Integration 9 MAINTENANCE 10 How to Replace Lamp s 10 Step by Step Lamp Replacement 10 How to Clean your Product 11 STORAGE 11 ULTRAVIOLETS UVC 11 ELECTRICAL RATINGS POWER CONSUMPTION AVAI...

Страница 3: ...models are specialized products a sizing calculation must be prepared with your Sanuvox representative for your specific installation For information or recommendations on how to size your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works The IL Coil Clean is an industrial evaporator coil cleaner that is installed in front of the coil of the air treatment systems I...

Страница 4: ...ean orMULTI ILCoilClean aluminum extrusion a packaged UV lamp a support rod a ballast box and a basic installation kit The installation kit includes a UV caution decal a maintenance decal cotton gloves hex bolts 2 Phillips head screws 2 self tapping screws 2 nuts 2 lock washers 2 electrical connectors 2 clamp assemblies 2 mounting flanges 2 and a coupler Setup While selecting the appropriate locat...

Страница 5: ...stalled vertically more rods and flanges are needed 3 Measure and cut the rod to desired length or assemble several rods using couplers if necessary NOTE For lengths over 66 or when using multiples IL Coil Clean units multiple support rods may be joined together by using a coupler included Refer to Using the Coupler to Join Multiple 3 4 Support Rods on page 8 4 Place the mounting flanges on both e...

Страница 6: ... the mounting flanges Recommendations To ensure you protect users from direct UV exposure use a interlok switch on the access door The switch will stop the operation of the IL Coil Clean when the door is opened 10 Installation of the ballast box Remove the Phillips screws 4 from the ballast box cover Set aside the bag containing the Gaynor plug and lamp boot Mount the ballast box outside the air h...

Страница 7: ...to the connection The lamp boot does not cover the entire end cap of the UV lamp but only approximately 3 4 15 There remains only the connection of the power supply which must be carried out by a certified electrician With the ballast box cover removed install a connector on the round knockout on the bottom of the ballast box Next pull an appropriate power cable into the box Insert the white neutr...

Страница 8: ...embly is completed with the coupler tube inside thus joining two support rods You can now install IL units with longer support rods STEP 1 STEP 2 STEP 3 STEP 4 Using the Coupler to Join Multiple 3 4 Support Rods In the event that the AHU side panels that supports the IL Coil Clean assembly are wider than the included 3 4 support rod or that the installation required multiple IL Coil Clean units th...

Страница 9: ...ast you will notice only one wire set in the ballast box as well as a black cap covering the second LED emplacement If there is two 2 ballasts there will be two wire set and two LED GREEN UV UNIT ON The unit is functioning normally YELLOW UV LAMP NEEDS REPLACEMENT Notifies the user that the UV lamp has reached the end of its lifespan and must be replaced FLASHING RED UV LAMP FAILURE Lamp has faile...

Страница 10: ...ut gloves Step by Step Lamp Replacement 1 Disconnect all power before performing any maintenance or service With the power off remove the lamp from the reflector and unplug it 2 Release the old lamp from the reflector brackets and remove it CAUTION Use caution when removing and inserting UV lamps from the metal spring clamps 3 Use a new UV lamp Plug in the new lamp and place the rubber tip over th...

Страница 11: ...N AVAILABLE VOLTAGE The IL Coil Clean and its various models has a power consumption that varies according to its lamp length 1 0 amps for 40 lamps 1 25 amps for 50 lamps and 1 5 amps for 60 lamps See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE...

Страница 12: ...anty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure to specify product name NOTE IF YOU EXPERIENCE A PRO...

Отзывы: