background image

Sanuvox Technologies Inc, © 2019 All rights reserved. March 2022 EN v.1

Instruction Manual

Photos illustrating products are non contractual.

IL COIL CLEAN 

& ITS VARIOUS MODELS

UV COIL CLEANER

Commercial Model

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit 

or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.

 NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP. 

1. 

Installation and servicing of UV units or systems  (in an 

air conditioning system or not) can be hazardousOnly 

trained and qualified service personnel

 should install, 

repair or service equipment.

2.  Untrained personnel can perform basic maintenance 

functions  such  as  replacing  lamp(s)  and/or  filter(s).  All 

other operations should be performed by trained service 

personnel.

3.  The unit is not to be used by persons (including children) 

with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge.

 

 CAUTION: Unit is not a toy. Keep away from 

unsupervised children. Do not leave children unattended 

with the unit.

4.  DO NOT hang onto the UV unit or system

5.  Some UV units or systems could be heavy: Make sure 

you have a minimum of 2 people to safely move or install 

these UV units or systems, and make sure you adopt the 

most ergonomic position possible (use UV unit or system 

handles, if applicable).

 

 CAUTION:  Installing or maintaining heavy equipment, 

especially overhead, can cause back pain or other injuries. 

6.  When installing or servicing an overhead UV unit or system, 

be careful not to fall off the stepladder. Furthermore, make 

sure the UV unit or system latches are always in place to 

prevent falling parts.

 

 CAUTION: Some parts of some UV units and systems 

may open suddenly if the UV unit or system is installed 

high up without its locks.

7.  Units that are obviously damaged must not be operated.

8. 

 CAUTION: When working on the UV unit or system, 

observe precautions on the literature, tags and labels 

attached to the UV unit or system, and all other safety 

precautions considered as best practices in the HVAC 

industry, if applicable.

9.  When applicable, local regulation may comprise more 

restrictive  installation  and/or  certification  requirements. 

The aforementioned requirements prevail on those of this 

document and the installer agree to conform to these at his 

own expense.

10.  Follow all the safety instructions outlined in this document 

and respect all local and national codes applicable.

11.  All UV units or systems contain a UV-C source. Damage to 

the housing or unintended use of the UV unit or system may 

result in harmful UV-C leaks. UV-C may, even in little doses, 

cause harm to the eyes and skin.

12.  Never expose eyes or skin to an operating UV lamp. 

Therefore, before installing or performing maintenance 

on the UV unit or system, TURN OFF AND DISCONNECT 

the UV unit or system from all power sources (there 

may be more than one switch to disconnect) and also 

disconnect the HVAC system, is applicable.

 

 CAUTION: Electrical shock may cause injuries or 

possibly  death.  FIRST  AID  INSTRUCTIONS:  If  injured, 

consult a doctor.

13.  UV rays may damage certain types of filters (polymer or 

plastic); please keep the UV unit or system light away from 

shining directly on plastic.

14.  When installing or performing maintenance on the UV unit 

or system, it is recommended to wear safety gloves. In 

order to avoid reduced performance of lamp(s), do not 

touch lamp glass without gloves.

15.  Just like conventional fluorescent lamps, UV lamps contain 

a small quantity of mercury: if a lamp breaks, clean and 

dispose of with care. UV lamps can be disposed/recycled 

after use in the same way as any other fluorescent lamps. 

Contact and follow the specific instructions of your local 

and national authorities.

16. 

Use  only  specified  SANUVOX  branded  replacement 

UV lamps for your UV unit or system. Use of any other 

lamps will void your warranty and can result in damage to 

the UV unit or system.

17.  Sanuvox UV units or systems are not waterproof. DO NOT 

INSTALL OUTDOORS OR IN WET LOCATION unless 

specified otherwise.

18.  The use of a UV unit or system is a supplement to and 

not a substitute for standard infection control practices; 

users must continue to follow all current infection control 

practices, including those related to the cleaning and 

disinfection of environmental surfaces.

SAVE THESE INSTRUCTIONS

For any inquiries on a UV unit or system, contact :

Robert Smith 

146 Barr St, Saint-Laurent

Quebec, CA, H4T 1Y4 

1-888-726-8869 

[email protected]

Содержание IL COIL CLEAN

Страница 1: ...d to the UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructio...

Страница 2: ...ion 5 Using the Coupler to Join Multiple 3 4 Support Rods 8 Step by Step Coupler Installation 8 OPERATION 9 How to Operate your Product 9 How to Read the LED Status Display 9 Dry Contacts for Building Automation Integration 9 MAINTENANCE 10 How to Replace Lamp s 10 Step by Step Lamp Replacement 10 How to Clean your Product 11 STORAGE 11 ULTRAVIOLETS UVC 11 ELECTRICAL RATINGS POWER CONSUMPTION AVAI...

Страница 3: ...models are specialized products a sizing calculation must be prepared with your Sanuvox representative for your specific installation For information or recommendations on how to size your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works The IL Coil Clean is an industrial evaporator coil cleaner that is installed in front of the coil of the air treatment systems I...

Страница 4: ...ean orMULTI ILCoilClean aluminum extrusion a packaged UV lamp a support rod a ballast box and a basic installation kit The installation kit includes a UV caution decal a maintenance decal cotton gloves hex bolts 2 Phillips head screws 2 self tapping screws 2 nuts 2 lock washers 2 electrical connectors 2 clamp assemblies 2 mounting flanges 2 and a coupler Setup While selecting the appropriate locat...

Страница 5: ...stalled vertically more rods and flanges are needed 3 Measure and cut the rod to desired length or assemble several rods using couplers if necessary NOTE For lengths over 66 or when using multiples IL Coil Clean units multiple support rods may be joined together by using a coupler included Refer to Using the Coupler to Join Multiple 3 4 Support Rods on page 8 4 Place the mounting flanges on both e...

Страница 6: ... the mounting flanges Recommendations To ensure you protect users from direct UV exposure use a interlok switch on the access door The switch will stop the operation of the IL Coil Clean when the door is opened 10 Installation of the ballast box Remove the Phillips screws 4 from the ballast box cover Set aside the bag containing the Gaynor plug and lamp boot Mount the ballast box outside the air h...

Страница 7: ...to the connection The lamp boot does not cover the entire end cap of the UV lamp but only approximately 3 4 15 There remains only the connection of the power supply which must be carried out by a certified electrician With the ballast box cover removed install a connector on the round knockout on the bottom of the ballast box Next pull an appropriate power cable into the box Insert the white neutr...

Страница 8: ...embly is completed with the coupler tube inside thus joining two support rods You can now install IL units with longer support rods STEP 1 STEP 2 STEP 3 STEP 4 Using the Coupler to Join Multiple 3 4 Support Rods In the event that the AHU side panels that supports the IL Coil Clean assembly are wider than the included 3 4 support rod or that the installation required multiple IL Coil Clean units th...

Страница 9: ...ast you will notice only one wire set in the ballast box as well as a black cap covering the second LED emplacement If there is two 2 ballasts there will be two wire set and two LED GREEN UV UNIT ON The unit is functioning normally YELLOW UV LAMP NEEDS REPLACEMENT Notifies the user that the UV lamp has reached the end of its lifespan and must be replaced FLASHING RED UV LAMP FAILURE Lamp has faile...

Страница 10: ...ut gloves Step by Step Lamp Replacement 1 Disconnect all power before performing any maintenance or service With the power off remove the lamp from the reflector and unplug it 2 Release the old lamp from the reflector brackets and remove it CAUTION Use caution when removing and inserting UV lamps from the metal spring clamps 3 Use a new UV lamp Plug in the new lamp and place the rubber tip over th...

Страница 11: ...N AVAILABLE VOLTAGE The IL Coil Clean and its various models has a power consumption that varies according to its lamp length 1 0 amps for 40 lamps 1 25 amps for 50 lamps and 1 5 amps for 60 lamps See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE...

Страница 12: ...anty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure to specify product name NOTE IF YOU EXPERIENCE A PRO...

Отзывы: