USER INSTRUCTIONS

WARNINGS

IF WATER ISSUES FROM THE TEMPERATURE/PRESSURE 

RELIEF  VALVE  ON  THE  PREMIERPLUS  CYLINDER 

SHUT DOWN THE BOILER. DO NOT TURN OFF ANY 

WATER SUPPLY. CONTACT A COMPETENT INSTALLER 

FOR  UNVENTED  WATER  HEATERS  TO  CHECK  THE 

SYSTEM.

DO NOT TAMPER WITH ANY OF THE SAFETY VALVES 

FITTED TO THE PREMIERPLUS SYSTEM. IF A FAULT IS 

SUSPECTED CONTACT A COMPETENT INSTALLER.

BENCHMARK 

The PremierPlus cylinder is covered by the Benchmark 

Scheme  which  aims  to  improve  the  standards  of 

installation and commissioning of domestic heating 

and hot water systems in the UK and to encourage 

regular  servicing  to  optimise  safety,  efficiency  and 

performance.

Benchmark is managed and promoted by the Heating 

and Hotwater Industry Council. For more information 

visit www.centralheating.co.uk.

Please ensure that the installer has fully completed 

the  Benchmark  Checklist  (Page  22  and  23)  of  this 

manual and that you have signed it to say that you 

have  received  a  full  and  clear  explanation  of  its 

operation. The installer is legally required to complete 

a commissioning checklist as a means of complying 

with the appropriate Building Regulations (England 

and Wales).

All installations must be notified to Local Area Building 

Control  either  directly  or  through  a  Competent 

Persons Scheme. A Building Regulations Compliance 

Certificate will then be issued to the customer who 

should, on receipt, write the Notification Number on 

the Benchmark Checklist.

This product should be serviced regularly to optimise 

its  safety,  efficiency  and  performance.  The  service 

engineer should complete the relevant Service Record 

on the Benchmark Checklist after each service.

The  Benchmark  Checklist  may  be  required  in    the 

event  of  any  warranty  work  and  as  supporting 

documentation  relating  to  home  improvements 

in  the  optional  documents  section  of  the  Home 

Improvements Pack.  

TEMPERATURE  CONTROLS  –  DIRECT    UNITS  

IMMERSION  HEATER(S)  

A  combined  adjustable  thermostat  and  thermal 

cut-out is provided for each immersion heater. The 

thermostat  is  factory  set  to  give  a  water  storage 

temperature of approx. 55° to 60°C. Access to the 

thermostat can be made by opening the immersion 

heater cover - DISCONNECT THE ELECTRICAL SUPPLY 

BEFORE  OPENING  THE  COVER(S).  Temperature 

adjustment  is  made  by  inserting  a  flat  bladed 

screwdriver  in  the  slot  on  the  adjustment  disc  on 

top of the thermostat and rotating. The adjustment 

range 1 to 5 represents a temperature range of 10° 

to 70°C (60°C will be approximately position 4). If in 

any doubt contact a competent electrician.

DO  NOT  bypass  the  thermal  cut-out(s)  in  any 

circumstances.

TEMPERATURE CONTROLS - INDIRECT UNITS  

The  PremierPlus  cylinder  units  are  fitted  with  an 

indirect  thermostat  and  thermal  cut-out.  These 

controls  must  be  wired  in  series  with  the  2  port 

motorised zone valve supplied to interrupt the flow 

of  primary  water  around  the  heat  exchanger  coil 

when  the  control  temperature  has  been  reached. 

The  controls  are  located  within  the  lower  terminal 

housing along with the immersion heater thermostat. 

The thermostat is factory set to give a water storage 

temperature of approx. 55° to 60°C. Access to the 

thermostat  can  be  made  by  opening  the  terminal 

housing  cover  -  DISCONNECT  THE  ELECTRICAL 

SUPPLY BEFORE OPENING THE COVER. Temperature 

adjustment  is  made  by  inserting  a  flat  bladed 

screwdriver in the adjustment knob and rotating. The 

minimum thermostat setting is 10°C. The adjustment 

range 1 to 5 represents a temperature range of 30° 

to 70°C (60°C will be approximately position 4). If in 

any doubt contact a competent electrician. 

An immersion heater is also provided for use should 

the  indirect  heat  source  be  shut  down  for  any 

purpose. The immersion heater control temperature 

is set using the immersion heater thermostat.

DO  NOT  bypass  the  thermal  cut-out(s)  in  any 

circumstances.

FLOW PERFORMANCE

When initially opening hot outlets a small surge in 

flow  may  be  noticed  as  pressures  stabilise.  This  is 

quite normal with unvented systems. In some areas 

cloudiness may be noticed in the hot water. This is 

due to aeration of the water is quite normal and will 

quickly clear.

OPERATIONAL FAULTS

Operational  faults  and  their  possible  causes  are 

detailed in the Fault Finding section of this book. It 

is recommended that faults should be checked by a 

competent installer.

The  air  volume  within  the  expansion  vessel  will 

periodically require recharging to ensure expanded 

water is accommodated within the unit. A discharge of 

water 

INTERMITTENTLY

 from the expansion valve will 

indicate the air volume has reduced to a point where 

it can no longer accommodate the expansion.

Содержание PremierPlus 100

Страница 1: ...r s and thermal controls l Factory fitted temperature pressure relief valve l Cold water combination valve assembly l Expansion vessel and mounting bracket l Tundish l Motorised valve indirect models...

Страница 2: ...istance The outer casing is a combination of resilient thermoplastic mouldings and plastic coated corrosion proofed steel sheet All products are insulated with CFC free polyurethane foam to give good...

Страница 3: ...55 Indirect 100 125 25 120 147 27 150 184 31 170 203 33 210 251 41 250 300 50 300 360 60 Table1 unit weights WATER SUPPLY Bear in mind that the water supply to the property will be supplying both the...

Страница 4: ...unit The fittings are threaded 3 4 BSP male parallel should threaded pipe connections be required COLD FEED A 22mm cold water supply is recommended however if a 15mm 1 2 supply exists which provides...

Страница 5: ...old feed to the unit A swept tee joint is available as an accessory order code no 94 970 033 The secondary return pipe should be in 15mm pipe and incorporate a check valve to prevent backflow A suitab...

Страница 6: ...00 1090 16 4 27 21 170 306 925 1216 173 170 315 354 925 1216 16 0 30 24 210 306 1184 1474 215 210 315 354 1184 1474 18 3 34 26 250 306 1394 1726 257 250 315 354 1391 1726 20 38 27 300 306 1715 2040 31...

Страница 7: ...that is used by the safety devices the manifold should be factory fitted as part of the hot water storage system unit or package Tundish 3 54 The tundish should be vertical located in the same space a...

Страница 8: ...prevent contact whilst maintaining visibility and d discharges at high level e g into a metal hopper and metal downpipe with the end of the discharge pipe clearly visible or onto a roof capable of wi...

Страница 9: ...outlet sizes NOTE The above table is based on copper tube Plastic pipes may be of different bore and resistance Sizes and maximum lengths of plastic should be calculated using data prepared for the t...

Страница 10: ...suitable controller to BSEN 60730 The PremierPlus MUST be earthed All wiring to the unit must be installed in accordance with the latest IEE Wiring Regulations and the circuit must be protected by a s...

Страница 11: ...with a contact separation of at least 3mm in both poles All connections are made to the terminal block located under the terminal cover mounted on the side of the unit The supply cable s must be rout...

Страница 12: ...1 N 2 3 HTG ON DHW ON L N 2 3 1 L 2 N 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Supply 1 2 3 G W Bl 2 0 GY 3 G 1 Br Bl 2 0 L N Programmer Boiler Pump Zone valve HTG Premier Plus terminal block 1 3 2 2 Ro...

Страница 13: ...he temperature can be adjusted by inserting a flat bladed screwdriver in the adjustment knob on top of the immersion heater thermostat and rotating The adjustment range 1 to 5 represents a temperature...

Страница 14: ...r time the immersion heater gasket may become stuck to the mating surface To break the seal insert a round bladed screwdriver into one of the pockets on the immersion heater and gently lever up and do...

Страница 15: ...LY BEFORE OPENING THE COVER S Temperature adjustment is made by inserting a flat bladed screwdriver in the slot on the adjustment disc on top of the thermostat and rotating The adjustment range 1 to 5...

Страница 16: ...pply off 2 Check and open stock cock 2 Strainer blocked 2 Turn off water supply Remove strainer and clean see maintanance section 3 Cold Water Combination Valve incorrectly fitted 3 Check and refit as...

Страница 17: ...ion body 95 605 900 10 Pressure reducing valve cartridge 3 5bar 95 605 898 11 Temperature Pressure Relief Valve 95 605 810 12 Expansion vessel 12 litre 100 120 and 150 litre models 95 607 863 13 Expan...

Страница 18: ...losses based on an ambient air temperature of 20 C and a stored water temperature of 65 C ENVIROMENTAL Products are manufactured from many recyclable materials At the end of their useful life they sho...

Страница 19: ...d to frost nor has it been tampered with or been subjected to misuse or neglect No factory fitted parts have been removed for unauthorised repair or replacement The BenchmarkTM Commissioning Checklist...

Страница 20: ...20 notes...

Страница 21: ...21 notes...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 0208 5730574 Parts Center Network 65 Business Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Ne...

Отзывы: