A
Terminal board for environmental sensors
B
Cable-gland for environmental sensors
C
DIP-switch for the configuration of environmental
sensors
o
Connect RS-485 comms cable to terminals M1 and M2 (in-out connection) to ES977 board by
using a “Belden 3106A Paired EIA Industrial RS-485 PLTC/CM” cable and fasten the cable braiding
to the copper cable glands.
o
Set up the rotary switches for Modbus address on ES1004 board and DIP-switch SW1 for
termination enable/disable on ES977 board.
M1
RS-485 IN
M2
RS-485 OUT
F
RS-485 fuses
A
Rotary-switch
Modbus address
strings 1-8
B
Rotary-switch
Modbus address
strings 9-16
SW1
Termination DIP-
switch
Connect the strings.
o
Open the disconnect switch, open the fuse-holders
, close the string box cover.
o
Plug the contacts. Pull connectors to check that plugging is correct.
A
Connection of string positive pole
B
Connection of string negative pole
C
Positive pole fuses, strings 1-8
D
Negative pole fuses, strings 9-16
E
Negative pole fuses, strings 1-8
F
Negative pole fuses, strings 9-16