Preparation before installing
1.Check the Qty of components according to packinglist or parts list.
2.Check the Qty of materials according to parts list.
3.Check if there is damage on the surface of product components or not.
4.A grounded outlet needed as recommend to use at least 16A with a fuse of the
leakage protection switch.
5.A professional personnel or electricians is needed when installing electrical
components.
If can not satisfy above conditions, please stop installing immediately and contact the
dealer.
Tool
Screwdriver
3m Tape Measure
2.5mm Hexagon Wrench
Technology parameters
Rated Voltage
:
AC230V
Rated Power
:
2100W
Rated Current
:
8A
Rated frequency
:
50~60HZ
Insulated Resistance
:
>20MΩ
Load parameter
Back/Leg heater
:
AC230V/300W
Front heater
:
AC230V/150W
Fan
:
DC12V/5W
Color Light
:
DC12V/5W