9. ELECTRICAL SYSTEM
9-6
Starter relay
Z
Inter-terminal voltage is 12V. Test the direct
connection of positive and negative poles with the
multimeter.
Z
If the starter relay clicks and connected, the starter
relay is OK.
Z
When there is no voltage of 12V, they are not
connected, the starter relay is OK.
Note: Do not apply battery voltage on the starter
relay for more than 2 seconds. This will result in
overheating or damaging the relay coil.
Z
Measure the coil resistance with the multimeter. If
the resistance exceeds the specified value, replace
the starter relay.
The multimeter is set to 1x10Ω.
Starter relay coil resistance: 3-5Ω
Auxiliary starter relay
Z
Apply 12V voltage between the positive and
negative terminals of the starter relay. Test the
connection between A and B with the multimeter.
Z
If the starter relay clicks and is connected, the
starter relay is OK.
Z
When there is no voltage of 12V, they are not
connected, the starter relay is OK.
The multimeter is set to 1x10Ω.
Auxiliary starter relay coil resistance: 90-100Ω