18 / 32
0.0
0.0
180.0
90.0
0.0
10.0
120.0
120.3
10.0
※Next, go to <③
Adjustment of amplitude>.
ON/OFF
key
※Adjust the frequency to the frequency
that raises the work feeding speed to the
fastest.
Freq
▲▼
keys
※Raise the frequency by several tenths
of one Hz to the point at which the work
feeding speed is the fastest.
First, make an adjustment aiming the
output% at around 10%.
Vol
▲▼
keys
Vol
▲▼
keys
※To next page
Freq
▲▼
keys
Vol
▲▼
keys
④
Adjustment of amplitude
※Perform the
following in the
forced operation:
Freq
▲▼
keys
※If the voltage is
too high or too low,
change the voltage%.
※For the distinction between the
full wave and the half wave, confirm
the model, etc. of the drive.
In the case of half wave, set the frequency to 90Hz by
using the Freq
▲▼
keys.
<Meaning of RUN lamp status>
ON: In operation by remote control
OFF: Operation at a stop (when remote
control is OFF)
Quick blinking: In forced operation
Slow blinking: Forced operation at a stop
* Forced operation means
⇒
Forcedly starting/stopping the operation by
pressing the ON/OFF button whether the
operation is remote-controlled or not
In the case of full wave,
the frequency is set to
180Hz (factory setting).
In the case of half wave,
the frequency is set to
90Hz.