14 What if there are problems?
If the scale detects and error when measuring, the following is displayed.
Display
Cause
Remedy
0_Ld
The maximum load capacity of 150 kg was
exceeded.
Do not load the unit with over 150 kg.
Lo
The batteries are almost empty.
Replace the batteries (see page 21 and
29).
The electrical resistance between the elec-
trodes and the sole of your foot is too high
(e.g. if you have tough calluses).
Repeat the measurement barefoot. If
necessary, moisten the soles of your
feet slightly. If necessary, remove the
calluses from the soles of your feet.
The fat percentage is outside the meas-
urable range (less than 5% or greater
than 50%).
Repeat the measurement barefoot or, if
necessary, moisten the soles of your
feet slightly.
The water percentage is outside the
measurable range (less than 36% or
greater than 70%).
Repeat the measurement barefoot or, if
necessary, moisten the soles of your
feet slightly.
Err
The muscle and bone percentages are
outside the measurable range (age and
gender related).
Repeat the measurement barefoot or, if
necessary, moisten the soles of your
feet slightly.
The batteries in the control unit are
completely empty.
Replace the batteries (see page 21).
No display
The batteries in the control unit are not
inserted correctly.
Check to ensure that the polarity is cor-
rect (see page 21)
No measurement possible
Possible errors
Remedy
The scale was not activated before you stood on it.
If you step on the scale before "0.0 KG" is dis-
played, the scale will not work correctly.
Activate the scale correctly (wait for "0.0
KG") and repeat the measurement.
Switch on the control unit first before the
measurement. If necessary, wait 30 sec-
onds, then repeat the measurement.
Cordless connection between scale and control
unit is interrupted.
Briefly remove, then reinsert the batteries of
the scale and the control unit; the scale
sends an audible signal when you insert the
batteries.
Keep away from following electromagnetic
sources: Power lines, television or computer
sets, bike computers, mobile phones,
weather stations.
The control unit is too far away from the scale.
Reduce the distance between the scale and
control unit; maximum distance is 2 metres.
The batteries in the scale are empty.
Replace the batteries (see page 21).
Incorrect weight measurement
Possible errors
Remedy
Scale is on carpeting.
Place the scale on a level and solid surface.
Incorrect zero point of scale.
Activate the scale until a signal sounds, wait
approximately 4 seconds, repeat measure-
ment.
Содержание SBG 58
Страница 62: ...62 1 63 2 63 3 64 4 66 5 66 6 67 7 68 8 69 9 70 10 71 11 74 12 74 13 74 14 75 15 76 16 76 3 1 5 AAA 3 1 5 AAA...
Страница 63: ...63 Sanitas 1 2 100 LB ST 2...
Страница 64: ...64 3 150 330 24 100 0 2 1 4 0 1 Beurer 2004 108 EC...
Страница 65: ...65...
Страница 66: ...66 4 1 2 3 SET 4 S 5 T 6 ON 5 74 SET LB ST 69 3 AAA 3 AAA...
Страница 67: ...67 6 2 82 6 40 4...
Страница 68: ...68 7 15 10...
Страница 69: ...69 8 SET KG S T LB ST SET 10 ON 0 0 SET 1 10 100 220 3 03 7 03 10 100 1 5 S T SET 1 2 3 2 4 30 4 4 6 30 5 1...
Страница 70: ...70 9 1 ON 0 0 KG 2a 0 0 KG 2b S 0 0 KG 1 BF 1 2 2 3 3 4 Kcal 4 0 0...
Страница 73: ...73 AMR AMR Active Metabolic Rate 1 5 AMR 18...
Страница 74: ...74 11 Lo 3 1 5 AAA 3 1 5 AAA 12 13 Pb Cd Hg 2002 96 EC WEEE Waste Electrical and Electronic Equipment...
Страница 75: ...75 14 0_Ld 150 150 Lo 66 74 5 50 36 70 Err 66 66 0 0 0 0 KG 30 2 66...