ALWAYS USE A SUFFICIENT NUMBER OF PEOPLE OR
MECHANICAL LIFTING EQUIPMENT TO PROTECT ALL
PERSONNEL FROM PERSONAL INJURY DURING THE
REMAINING STEPS.
1. Carefully lower the machine and place it where it will be
installed.
2. Level the unit by turning the bottom part of each leg
clockwise or counterclockwise (Fig. 1). The machine
MUST
be level to operate properly.
A MINIMUM 6” (152 MM) CLEARANCE MUST BE
MAINTAINED AT THE REAR AND SIDES OF THE
MACHINE FOR ADEQUATE VENTILATION.
3. Electrical and refrigeration specifications are
located on the data plate on the rear of the individual
machines. Consult local authorities for information
regarding plumbing and electrical codes in the area.
Note: All SaniServ machines should have their own
dedicated circuits whether they are cord connected
plug-in devices or hard wired units.
Introduction
Installation
ALWAYS CHECK ELECTRICAL SPECIFlCATIONS
ON THE DATA PLATE OF THE MACHINE. DATA
PLATE SPECIFICATIONS ALWAYS SUPERSEDE
ELECTRICAL INFORMATION IN THIS MANUAL.
FAILURE TO PROVIDE FOR PROPER EARTH
GROUND ACCORDING TO LOCAL APPLICABLE
ELECTRICAL CODES COULD RESULT IN
SERIOUS ELECTRICAL SHOCK OR DEATH.
DO NOT USE EXTENSION CORDS
DO NOT TURN MACHINE ON
WARNING
IMPORTANT
This manual provides a general system description of the SaniServ Frozen Beverage Dispensers. It has been prepared
to assist in the training of personnel on the proper installation, operation, and maintenance of the machines.
Read and fully understand the instructions in this manual before attempting
to
install, operate, or perform routine maintenance on the machines.
The following sections of the manual must be performed in sequence:
1. Installation
4. Assembly & Lubrication
2. Installer's Preoperational Check
5. Sanitizing & Operation
3. Disassembly & Cleaning
6. Consistency Adjustment
PAGE 1
Fig. 1
Minimum
Clearance
4”(102 mm) for
Counter Top
Models and
6”(152 mm) for
Floor Models
WARNING
Drip Tray Bracket
1
.
Remove the three (3) phillips head screws and three (3)
lock washers from the parts packet.
2. Align the drip tray bracket with the three weld nuts on
the bottom of the dispense head base (Fig 2).
3. Using a phillips head screwdriver, secure the drip tray
bracket to the bottom of the dispense head.
4. The removable drip tray slides into the support and is
secured by the bullet catches.
Drip Tray Drain Tube
This machine is equipped with a drip tray featuring a drain
stub. It is the installer's responsibility to provide a suitable
standard size 3/4" drain tube plumbed in accordance with all
applicable local, state, and federal codes.
NOTE: THE DRAIN TUBE INSTALLATION MUST PROVIDE
EASY ACCESS FOR DAILY CLEANING.
Fig. 2
Drip Tray Bracket Installation
INTRODUCTION & INSTALLATION
Содержание WB Series
Страница 1: ...Operation Manual WB Series Frozen Beverage Dispensers Reliability from the team that Serves the Best...
Страница 24: ...Date Service Performed Serviceman s Signature Service Record SERVICE RECORD PAGE 20...
Страница 25: ...Date Service Performed Serviceman s Signature Service Record SERVICE RECORD PAGE 21...
Страница 26: ...PAGE 22 Notes...
Страница 27: ......