Function
Action
Display
Description
Commissioning
Peel off label, 1 x • wait for
1 x
(green)
1 x
Automatic background measurement starts
Note:
no
during background measurement
1 x / s
(red)
wait for
1 x
(green)
Background measurement finished, fitting ready for use
Normal operation (water flows)
Water flows:
ON
Special functions
Waterflow duration:
SETTING
(Factory setting approx. 1 s)
Press • 1 x for 2 s (min.) – then release
Press • 1 x for 5 s until 1 x
(red), then release
Press • 1 x (water flows) and keep pressing until the
desired water flow duration has been reached
1 x
(green)
1 x
(red)
1 x
(green)
Water flow duration: adjustable from 0 to 10 s
Acknowledgement
Continuous water flow:
ON
(Factory setting approx. 2 min)
Press • 1 x for 2 s (min.) – then release
Press • 1 x for 2-4 s
1 x
(green)
1 x
(green)
Continuous waterflow:
ON
Continuous water flow:
OFF
Press • 1 x
1 x
(green)
Acknowledgement (Automatic shut-off after „Continuous
water flow ON“ duration – if not switched off manually)
Continuous water flow:
SETTING
(Factory setting approx. 2 min)
Press • 1 x for 2 s (min.) – then release
Press • 1 x for 2-4 s
Press • 1 x and keep pressing until the desired
water flow time has been reached.
Flashing will start after 5 s
1 x
(green)
4 x
(green)
1 - 40 x
(red)
1 - 40 x
(red)
1 x
(green)
Continuous waterflow:
ON
Minimum: 1 x
(red) = 30 s
Maximum: 40 x
(red) = 20 min
Flow time confirmation
Acknowledgement
Pause:
ON
(Factory setting approx. 2 min.)
Press • 1 x for 2 s (min.) – then release
Press • 2 x
1 x
(green)
1 x
(green)
1 x
(red) fast flashing
whilst „Pause ON“ active
Confirmation Pause:
ON
Pause:
OFF
Press • 1 x
1 x
(green)
Acknowledgement (automatically goes back to normal
mode after 2 min – if not switched off manually)
New calibration
(Ambient background
measurement)
Press • 1 x for 2 s (min.) – then release
Press • 2 x
Press • 1 x for 5 s until 4 x
(red) - then
release – wait 15 s – do not place hands within
sensor area (water flows after 10 s), after
which an new ambient background measure-
ment will be defined
1 x
(green)
1 x
(green)
(red) fast flashing
4 x
(red)
1 x
(green)
Hygienic rinse
24 h / 12 h:
ON / OFF
(Factory setting: OFF)
Press • 1 x for 2 s (min.) – then release
Press • 1 x 24 s and hold until the desired
setting has been reached
Release button
1 x
(green)
1-3 x
(red)
1 x
(green)
Flashing will commence after 24 s
1 x
(red) = hygienic rinse
OFF
2 x
(red) = hygienic rinse
ON
- 12 h after last use
3 x
(red) = hygienic rinse
ON
- 24 h after last use
The flow duration for the hygienic rinse is identical to
that for the „Continuous water flow“
Acknowledgement
Emergency shut-off
(static object in sensor area)
Water flow ist switched off after a continuous detection period
of 90 s. A new background measurement is then carried out
Transmission power:
SETTING
(Sensor range)
Press • 1 x for 2 s (min.) – then release
Press • 2 x
Press • 1 x and hold, after 5 s 4 x
(red) then
continue to press until the desired transmis-
sion power is achieved. An automatic back-
ground measurement will then take place – do
not place hands in the sensor area during this
time (approx. 20 s)
1 x
(green)
1 x
(green)
(red) fast flashing
4 x
(red)
1 x
(green)
Transmission power: minimum = 1 x
(red)
maximum = 8 x
(red)
Acknowledgement
Display
Battery life
Lights up
(red)
Flashes
(red)
Level 1: Battery weak - water still flows
Level 2: Battery depleted - water does not flow
ENGLISH
8
DE/FR/IT/EN
Infratronic-N: Functions
•
= Infrared button (IR)
= Hand / Object in sensor area
= Flashing LED (
green
or
red
)