background image

3. Dimensions and overall measurements

0

1m

1%            

ø

 40

314 mm

max 30m

max 40m

max 50m

max 60m

373 mm

309 mm

256 mm

277 mm

36 mm

185 mm

92.5 mm

139.4 mm

Ver

tical Height - metr

es

Flow Rate L/min

max 70m

2m

3m

4m

5m

This unit is for domestic use only.

4. Performance Curve & Height and Length of the discharge pipe

6m

Max 7m

max 20m

max 10m

1

2

3

4

5

6

7

8

3

7

20            30           40             50           60            70           80            90          100          110         120

ø

 32

The discharge pipe size 
for Sanispeed must be 
32mm.

Содержание SANISPEED

Страница 1: ... follow instructions could result in poor functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included A B C E F G I x2 Discharge elbow D Air vent cover Metal...

Страница 2: ...6 mm 185 mm 92 5 mm 139 4 mm Vertical Height metres Flow Rate L min max 70m 2m 3m 4m 5m This unit is for domestic use only 4 Performance Curve Height and Length of the discharge pipe 6m Max 7m max 20m max 10m 1 2 3 4 5 6 7 8 3 7 20 30 40 50 60 70 80 90 100 110 120 ø 32 The discharge pipe size for Sanispeed must be 32mm ...

Страница 3: ... of the piperun I H 6 Connection to side inlets Use the rubber connector A for connection of pipes to the side inlets Secure with the metal hose clips G Cap off unused inlets with the end caps C provided after greasing the joints I H C G A G C G A G 7 Connection to lid inlets To connect to a lid inlet cut off the sealed cap with a hacksaw and connect using the rubber connector A provided Tighter w...

Страница 4: ...of 1 100 10mm per metre all the way to the drain Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem Orient the ope...

Страница 5: ...m the power supply before attempting any work on the unit The unit does not require any specific maintenance In case of a service requirement please call the Saniflo service engineer especially for any electrical work 15 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use 11 Electrical connection The electrical installation should be carried out...

Страница 6: ...16 Parts ...