5. Installation

The unit should be accessible for possible maintenance. 
It is supplied with floor fixing lugs to prevent it from moving during use.
If pumping vertically, always put the vertical before the horizontal at the start of the piperun.

I

H

6. Connection to side inlets

Use the rubber connector (

A

) for connection of pipes to the 

side inlets.
Secure with the metal hose clips (

G

). 

Cap off unused inlets with the end caps (

C

) provided, after 

greasing the joints. 

I

H

C

G

A

G

C

G

A

G

7. Connection to lid inlets

To connect to a lid inlet, cut off the sealed cap with a hacksaw and connect using 
the rubber connector (

A

) provided. Tighter with the metal hose clips (

G

).

Содержание SANISPEED

Страница 1: ... follow instructions could result in poor functioning of the unit This equipment benefits from the latest technological innovations concerning soundproofing To benefit fully from the advantages provided by this new generation of appliances it is important to comply with the installation instructions in section 5 2 List of Accessories included A B C E F G I x2 Discharge elbow D Air vent cover Metal...

Страница 2: ...6 mm 185 mm 92 5 mm 139 4 mm Vertical Height metres Flow Rate L min max 70m 2m 3m 4m 5m This unit is for domestic use only 4 Performance Curve Height and Length of the discharge pipe 6m Max 7m max 20m max 10m 1 2 3 4 5 6 7 8 3 7 20 30 40 50 60 70 80 90 100 110 120 ø 32 The discharge pipe size for Sanispeed must be 32mm ...

Страница 3: ... of the piperun I H 6 Connection to side inlets Use the rubber connector A for connection of pipes to the side inlets Secure with the metal hose clips G Cap off unused inlets with the end caps C provided after greasing the joints I H C G A G C G A G 7 Connection to lid inlets To connect to a lid inlet cut off the sealed cap with a hacksaw and connect using the rubber connector A provided Tighter w...

Страница 4: ...of 1 100 10mm per metre all the way to the drain Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit the resultant siphoning effect can suck out the water seal in the unit Fitting an air admittance valve capable of withstanding 10psi pressure BBA approved at the high point of the pipe run will overcome this problem Orient the ope...

Страница 5: ...m the power supply before attempting any work on the unit The unit does not require any specific maintenance In case of a service requirement please call the Saniflo service engineer especially for any electrical work 15 Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use 11 Electrical connection The electrical installation should be carried out...

Страница 6: ...16 Parts ...

Отзывы: