24
6.6 Using the SMART Control unit
Overview
Power indicator
Display of pump
activation 1 and 2
Validation of the task
Navigation
Return
Time
Power supply
voltage
Pump Intensity
Forced operation of
the pumps
Activation/deactivation of the pumps
Power Indicators
P1
P1
P2
P2
U=235V
10:45:55
I1=0.0A
I2=0.0A
AC
➤
➤
➤
➤
Pump activation/deactivation
Alarm indicator in real time, with identification of the problem detected for quick maintenance.
In the case of maintenance or replacement of a pump, it is possible to deactivate each pump
independently.
Press and hold for 5 seconds
to deactivate the pump. The
LED turns red and a cross is
displayed on the shut-down
pump.
Press again for 5 seconds to
reactivate the pump, the led
will turn green and the cross
will turn off.
P1
P1
P2
P2
U=234V
10:46:27
I1=0.0A
I2=0.0A
AC
➤
➤
➤
➤
Alarms display
A special window giving the alarm type and the alarm time remains open.
As soon as the fault disappears, return to the general screen on which an
alarm notification appears. To remove the alarm notification, simply press
one of the two forced-on buttons. Details of the alarms can be consulted
in the alarm log.
P1
P2
U=230V
10:46:14
I1=0.0A
I2=0.0A
AC
! ALARM !
ALARM
No AC
Start at10:45
10:45:45
AC
! ALARM !
ALARM
X