background image

 

 

26

 

3.3.2 DS3 Configuration

 

 

The DS3 Configuration menu: 

 

 

Used to view/change DS3 configuration. 
 
 

 

Содержание T3 Mux M13

Страница 1: ...anual Type the abstract of the document here The abstract is typically a short summary of the contents of the document Type the abstract of the document here The abstract is typically a short summary...

Страница 2: ...ates screen menus and parameters indicates keyboard keys Enter q s NOTE Notes inform the user of additional but essential information or features CAUTION Cautions inform the user of potential damage m...

Страница 3: ...3 This page is intentionally blank...

Страница 4: ...RS232 Port 7 2 3 6 Establishing Terminal Connection 8 2 4 Front Panel 12 2 4 1 DS1 Connectors 12 2 4 2 Push Buttons 13 2 4 3 System Status LED 13 Section 3 User Interface 14 3 1 System Management 15 3...

Страница 5: ...which carries up to 45 Mbps of 64 kbps channelized voice channels and rearranges the DS 3 framing into 28 T1 framings The major features of the T3Mux are as follows Cost Effective DS3 bandwidth consol...

Страница 6: ...aim immediately with the carrier keep the original packaging for damage verification and or returning the unit and contact Sangoma Customer Service 2 2 Shipping Contents T3Mux unit 5V 2A Power Supply...

Страница 7: ...r requiring a straight through cable not null modem Baud rate 115200 8 data bits 1 stop bit no flow control The RS232 port is used for Terminal Connection The Serial connection is established using a...

Страница 8: ...Tel exe from ftp ftp sangoma com T3Mux puttytel exe 2 Start PuttyTel exe on you Windows PC 3 Select Serial port settings as shown on this screenshot 4 Initialize the terminal session by clicking on Op...

Страница 9: ...9 Alternatively T3Mux can accept Telnet connections over TCP IP...

Страница 10: ...10 It is important to select Passive Telnet negotiation mode in Connection Telnet...

Страница 11: ...11 Once the configuration options are selected please click Open you should see the Login prompt of the Telnet Server...

Страница 12: ...onnector each in a DSX pinout 1 A straight through cable CABL 614G can be used to connect directly to CSU DSU boards such as Sangoma s A108DE 2 A split cable CABL 630 should be used to connect Sangoma...

Страница 13: ...a Port is shown as Green when the T1 line is Operational no Alarms The Status of a Port is shown as Red when the T1 line is non Operational there are Alarms To find out what are the Alarms please refe...

Страница 14: ...14 Section 3 User Interface This section describes the Menu driven user interface of the T3Mux Here is the structure of Menu tree...

Страница 15: ...15 3 1 System Management The System Management menu Used to view system status and change system configuration...

Страница 16: ...16 3 1 1 System Status The System Status screen Displays version and temperature information which is important for technical support personnel...

Страница 17: ...System Configuration menu Used to set IP Configuration Telnet Password and MAC Address for the LAN Connection The default user name for LAN Connection is admin password sangoma The RS232 Connection do...

Страница 18: ...Mask Default Gateway and Primary DNS Server will also be required By default the device is configured with static IP Address of 192 168 10 1 and Net Mask of 255 255 255 0 The NetBIOS Microsoft Network...

Страница 19: ...19 3 2 DS1 Interface The DS1 Interface menu Used to view Status of T1 lines configure T1 line s and control the T1 Loopback...

Страница 20: ...20 3 2 1 DS1 Status The T1 Status screen Displays an Alarm at T1 level Only the highest severity alarm is shown For example if both LOS and OOF are present only LOS will be shown...

Страница 21: ...y except for the Clock option The Clock Source options should be interpreted as follows Normal Clock the clock is delivered from Upstream from DS3 side if the Upstream clock is not available recover t...

Страница 22: ...rates how the T3Mux acts as a pass through for T1 Master Clock coming from Upstream T1 Master Clock DS3 T1 Normal Clock Figure 3 2 2 1 3 2 3 DS1 Loopback The T1 Loopback menu Used to view and control...

Страница 23: ...When a T1 Local Loopback is enabled all data that is output by the Transmitter will be routed to the Receiver Local Loopback is illustrated on Figure 3 3 3 1 Figure 3 3 3 1 When a T1 Line Loopback is...

Страница 24: ...24 3 3 DS3 Interface The DS3 Interface menu Used to view Status of DS3 line configure DS3 and control the DS3 Loopback...

Страница 25: ...25 3 3 1 DS3 Status The DS3 Status menu Used to view DS3 Alarms...

Страница 26: ...26 3 3 2 DS3 Configuration The DS3 Configuration menu Used to view change DS3 configuration...

Страница 27: ...of Local Loopback in Framer Digital Interface 2 Control of Local and Line Loopback in LIU Analog Interface When a Local Loopback is enabled all data that is output by the Transmitter will be routed to...

Страница 28: ...ll data that is received will be output to the Transmitter Line Loopback is illustrated on Figure 3 2 3 1 This is the diagram of DS3 Line Loopback in LIU Figure 3 2 3 1 This is the diagram of DS3 Loca...

Страница 29: ...u Used to Restore Configuration to its default state both in the volatile memory RAM and in non volatile storage EEPROM The Restart System Module option will restart the firmware so the current settin...

Страница 30: ...ent using serial port and you are ready for firmware upgrade To start updating firmware you need to reset or reboot your T3Mux When your T3Mux is boot up the lights of the ports will flash about 10 se...

Отзывы: