1.3  The  monitor  power  wire  consists  of  3  different  colors  of  wires.  The 

Black wire should be connected to the ground. The Red wire should 

be connected to the vehicle’s continuous power supply. The Blue wire 

should  be  connected to ignition  switch,  when  switched  to  “ON”,  the 

blue wire is connected with 12V power. 

The  monitor  starts  to  work  after  it  is  powered.  At  this  time  the  monitor 

cannot  receive  any  information  as  the  transmitters  are  not  installed.  The 

screen  shows  “NSP”,  which  means  there  are  “No  Transmitters 

Programmed”. 

 

2 Programming of Monitor 

Through  the  monitor,  the  user  can  program  up  to  38  transmitters  ID 

number and the standard pressure for each wheel. Operation steps are as 

following:   

 

3M Dual Lock

 

Содержание TPMS1209T02-ER

Страница 1: ...Page 1 of 28 TPMS1209T02 ER USER MANUAL Suzhou Sate Auto Electronic Co Ltd www sate com cn...

Страница 2: ...mitter ID 12 IV Installation of TPMS1209T02 ER Transmitter 12 1 Installation of Transmitter 13 2 Installation of Security Lock 14 V System Function of TPMS1209T02 ER 17 1 Full time Monitoring 17 2 Hig...

Страница 3: ...e information data to the monitor after received and magnified it The monitor can receive and deal with the data then display the pressure on the screen The monitor can issue different alarms if the t...

Страница 4: ...a suitable location to install the Monitor onto the dashboard Make sure to first scrub the surface of the location with alcohol Next strip off the liner of the 3M Dual Lock Fastener put the sticky sid...

Страница 5: ...hen switched to ON the blue wire is connected with 12V power The monitor starts to work after it is powered At this time the monitor cannot receive any information as the transmitters are not installe...

Страница 6: ...nd the monitor returns to normal mode Each transmitter has 4 groups of ID for example when program the transmitter with ID of 001 001 001 158 to front right tire position the user only needs to input...

Страница 7: ...shes Press up or down arrow key to adjust the value 6 When finish programming these 3 digits press S for 3 seconds to save with the screen flashes twice beep buzzes twice Then it will automatically sw...

Страница 8: ...t the value to 1 4 Once finished programming the first number press to program the second digit which flashes and then press up or down arrow key to adjust the value to 0 5 Once finished programming t...

Страница 9: ...y It is the base of the alarm record user can check the current date and time as follows 1 When finish programming the standard pressure press P to access interface for inquiry and programming of time...

Страница 10: ...Under any interface of system time inquiry press S for 3 seconds to start programming For example change the year to 09 under the year interface press S for 3 seconds the second digit flashes press up...

Страница 11: ...ey to switch to the pressure unit interface As shown below 2 Under any interface displaying temperature or pressure press S key for 3 seconds to start programming Take change the temperature unit as a...

Страница 12: ...tion to be deleted 3 Press S key for 3 seconds to delete with the screen flashes twice and beep buzzes twice to confirm the deletion Then it automatically switches to next transmitter location Note Af...

Страница 13: ...rmation on the screen When all of information were received by the monitor and the information are all normal the screen display ON 1 Installation of Transmitter 1 Remove the current tire valve cap 2...

Страница 14: ...ers or not 5 Once screwed onto the tire transmitter can sense the pressure inside the tire and transmit the data to the monitor and the information will appear on the screen within 6 minutes Note 1 Pl...

Страница 15: ...Lock and Transmitter should be installed at same time If the user chooses to use the lock please refer to the below part of lock installation Installation step of the Security Lock 1 First connect th...

Страница 16: ...three bolts inside the sockets on the Lock 2 Screw off the Transmitter 3 Remove the Transmitter together with the Lock from the Valve Note Install the lock or not will not influence the functions of...

Страница 17: ...with the reasonable method The red alarm lamp goes off only when the tire pressure returns to the normal level 3 Low pressure level 1 alarm Display mode Function the system will issue level 1 low pres...

Страница 18: ...tion icon and the audible alarm turn on together Treatment press any key to stop the audible alarm The red alarm lamp remains on and the display reverts to the normal mode The user should slow down th...

Страница 19: ...returns to normal level 6 High Temperature Alarm Display Mode Function When the temperature around the transmitter equals or exceeds 90 the system will issue the high temperature alarm Alarm Mode the...

Страница 20: ...arm and the system reverts to normal mode Then slow down and check the correspondent tire 8 Transmitter Trouble Alarm Display mode Function If one transmitter fails to work or the monitor cannot recei...

Страница 21: ...uiry 1 Under normal mode or pressure inquiry interface press P and S at the same time for 3 seconds to access the alarm record inquiry interface The screen with 0 is the first and most recent alarm re...

Страница 22: ...Page 22 of 28 Time year Time month Time date Time hour Time minute Then it will display the next alarm record in the same way as above...

Страница 23: ...Page 23 of 28 3 Press P and S at the same time to return to pressure inquiry interface...

Страница 24: ...Bm Input Voltage 12V 24V Current 60mA Operating Temperature 30 70 Storage Temperature 30 75 Transmitter Modulation Type FSK Mid frequency 434 1 MHz Transmitting Power 0 dBm Input Voltage 3 6V Battery...

Страница 25: ...transmitter battery work The transmitter battery can last about 5 7 years under normal conditions 4 How to deal with the transmitter trouble alarm issued by monitor If one transmitter fails to work or...

Страница 26: ...d contact us at 86 21 50792951 if necessary 7 When connected with vehicle s continuous power supply will the power of storage battery be used up if the vehicle parks for a long period The current draw...

Страница 27: ...od is one year and is subject to the time marked on the invoice 2 Any damages or faults due to improper use are not involved in the warranty commitment 3 Users are not allowed to open repair and refit...

Страница 28: ...nged 3 The warranty responsibility is subject to the conditions and limitations specified in the User Manual 4 TPMS1209T02 ER monitor should be connected with the continuous power supply and installed...

Отзывы: