background image

Page 15 of 28 

 

 

 

 

 

 

 

 

 

 

The  function  of  the  Lock  is  to  connect  the  Transmitter  and  the  Lock  by 

connecting the meshing part of them, and then fasten the Lock firmly by 

the three bolts in the sockets, thus the Transmitter with the Lock can be 

firmly  screwed  onto  the  valve  and  cannot  be  screwed  off  by  a  sudden 

force.   

Note: Security Lock and Transmitter should be installed at same time. If 

the  user  chooses  to  use  the  lock,  please  refer  to  the  below  part  of 

lock installation.   

 

Installation step of the Security Lock 

1.

 

First connect the meshing parts of the Lock and the 

Transmitter  to  make  them  an  integrated  part,  and 

then  screw  the  Transmitter  together  with  the  Lock 

firmly onto the valve, as shown in the lefet figure. 

2. Lock the Transmitter   

Use the wrench to fasten the three bolts inside the sockets on the Lock to 

Transmitter 

Security Lock 

Wrench 

Содержание TPMS1209T02-ER

Страница 1: ...Page 1 of 28 TPMS1209T02 ER USER MANUAL Suzhou Sate Auto Electronic Co Ltd www sate com cn...

Страница 2: ...mitter ID 12 IV Installation of TPMS1209T02 ER Transmitter 12 1 Installation of Transmitter 13 2 Installation of Security Lock 14 V System Function of TPMS1209T02 ER 17 1 Full time Monitoring 17 2 Hig...

Страница 3: ...e information data to the monitor after received and magnified it The monitor can receive and deal with the data then display the pressure on the screen The monitor can issue different alarms if the t...

Страница 4: ...a suitable location to install the Monitor onto the dashboard Make sure to first scrub the surface of the location with alcohol Next strip off the liner of the 3M Dual Lock Fastener put the sticky sid...

Страница 5: ...hen switched to ON the blue wire is connected with 12V power The monitor starts to work after it is powered At this time the monitor cannot receive any information as the transmitters are not installe...

Страница 6: ...nd the monitor returns to normal mode Each transmitter has 4 groups of ID for example when program the transmitter with ID of 001 001 001 158 to front right tire position the user only needs to input...

Страница 7: ...shes Press up or down arrow key to adjust the value 6 When finish programming these 3 digits press S for 3 seconds to save with the screen flashes twice beep buzzes twice Then it will automatically sw...

Страница 8: ...t the value to 1 4 Once finished programming the first number press to program the second digit which flashes and then press up or down arrow key to adjust the value to 0 5 Once finished programming t...

Страница 9: ...y It is the base of the alarm record user can check the current date and time as follows 1 When finish programming the standard pressure press P to access interface for inquiry and programming of time...

Страница 10: ...Under any interface of system time inquiry press S for 3 seconds to start programming For example change the year to 09 under the year interface press S for 3 seconds the second digit flashes press up...

Страница 11: ...ey to switch to the pressure unit interface As shown below 2 Under any interface displaying temperature or pressure press S key for 3 seconds to start programming Take change the temperature unit as a...

Страница 12: ...tion to be deleted 3 Press S key for 3 seconds to delete with the screen flashes twice and beep buzzes twice to confirm the deletion Then it automatically switches to next transmitter location Note Af...

Страница 13: ...rmation on the screen When all of information were received by the monitor and the information are all normal the screen display ON 1 Installation of Transmitter 1 Remove the current tire valve cap 2...

Страница 14: ...ers or not 5 Once screwed onto the tire transmitter can sense the pressure inside the tire and transmit the data to the monitor and the information will appear on the screen within 6 minutes Note 1 Pl...

Страница 15: ...Lock and Transmitter should be installed at same time If the user chooses to use the lock please refer to the below part of lock installation Installation step of the Security Lock 1 First connect th...

Страница 16: ...three bolts inside the sockets on the Lock 2 Screw off the Transmitter 3 Remove the Transmitter together with the Lock from the Valve Note Install the lock or not will not influence the functions of...

Страница 17: ...with the reasonable method The red alarm lamp goes off only when the tire pressure returns to the normal level 3 Low pressure level 1 alarm Display mode Function the system will issue level 1 low pres...

Страница 18: ...tion icon and the audible alarm turn on together Treatment press any key to stop the audible alarm The red alarm lamp remains on and the display reverts to the normal mode The user should slow down th...

Страница 19: ...returns to normal level 6 High Temperature Alarm Display Mode Function When the temperature around the transmitter equals or exceeds 90 the system will issue the high temperature alarm Alarm Mode the...

Страница 20: ...arm and the system reverts to normal mode Then slow down and check the correspondent tire 8 Transmitter Trouble Alarm Display mode Function If one transmitter fails to work or the monitor cannot recei...

Страница 21: ...uiry 1 Under normal mode or pressure inquiry interface press P and S at the same time for 3 seconds to access the alarm record inquiry interface The screen with 0 is the first and most recent alarm re...

Страница 22: ...Page 22 of 28 Time year Time month Time date Time hour Time minute Then it will display the next alarm record in the same way as above...

Страница 23: ...Page 23 of 28 3 Press P and S at the same time to return to pressure inquiry interface...

Страница 24: ...Bm Input Voltage 12V 24V Current 60mA Operating Temperature 30 70 Storage Temperature 30 75 Transmitter Modulation Type FSK Mid frequency 434 1 MHz Transmitting Power 0 dBm Input Voltage 3 6V Battery...

Страница 25: ...transmitter battery work The transmitter battery can last about 5 7 years under normal conditions 4 How to deal with the transmitter trouble alarm issued by monitor If one transmitter fails to work or...

Страница 26: ...d contact us at 86 21 50792951 if necessary 7 When connected with vehicle s continuous power supply will the power of storage battery be used up if the vehicle parks for a long period The current draw...

Страница 27: ...od is one year and is subject to the time marked on the invoice 2 Any damages or faults due to improper use are not involved in the warranty commitment 3 Users are not allowed to open repair and refit...

Страница 28: ...nged 3 The warranty responsibility is subject to the conditions and limitations specified in the User Manual 4 TPMS1209T02 ER monitor should be connected with the continuous power supply and installed...