KSwitch D4 MM Managed Ethernet Switch - Preliminary User Guide, Rev. 0.9
// 25
4.2.2.
DC Terminal Block Alarm Relay Contacts
The alarm relay output contacts in the middle of the DC terminal block connector detect an Ethernet link fail or power
supply fail. The alarm relay output is “Normal Close”.
Figure 7: Alarm Relay Contacts
8/10/12/14-port
18-port
1
Alarm system
2
Extra Power system
When attaching wires to the DC terminal block’s contacts consider:
•
DC terminal block pitch, 5.08 mm
•
Wire size range: Solid wire: 12~24 AWG and Stranded wire: 12~24 AWG
•
Wire length 3 m (9.84 ft.) maximum
•
Wire strip length 7 mm (0.28 in)
4.2.3.
Console Port Connector
The console port enables local management using a terminal emulator or a computer with terminal emulation
software. To connect a host PC to the console port connector, use a RJ45 to USB Type A connector cable to connect
the switch’s RJ45 console port to the host PC’s USB port.
Table 5: RJ45 Console Port Connector Pin Assignment
Pin
Signal
Pin
Signal
1,
-
5
-
2
-
6
GND
3
RD
7
-
4
TD
8
-
Console port features are:
Console cable RJ45 to USB Type A (male) to connect to computer’s USB (female) port
Baud rate: 115200bps
2