KSwitch D4 MM Managed Ethernet Switch - Preliminary User Guide, Rev. 0.9
// 24
4.2.
Top Side Features
4.2.1.
DC Terminal Block Power Contacts
Insert the positive and negative wires into the corresponding first power supply (PWR1+/-) and second power supply
(PWR2+/-) contacts on the DC terminal block and tighten the wire-clamp screws to prevent the wires from loosening.
The switch supports fault alarm notification for power.
Figure 6: Power Supply Contacts
8/10/12/14-port
18-port
1
PWR1 (+/- contacts)
2
PWR2 (+/-contacts)
When connecting the power follow the indicated polarity indicated for PWR1 +/- and
PWR2+/-:
The DC power must be connected to a well-fused power supply.
When attaching power wires to the DC terminal block’s power contacts consider:
•
DC terminal block pitch, 5.08 mm
•
Wire size range: Solid wire: 12~24 AWG and Stranded wire: 12~24 AWG
•
Wire length 3 m (9.84 ft.) maximum
•
Wire strip length 7 mm (0.28 in)
With multiple power sources connected to the switch, the switch utilizes the power supply
with the higher voltage or the most stable power supply.