Standard Front Panel:
The following interfaces are available with the KBox C-103-CFL:
24VDC input power (X101, optional 2
nd
power input X201)
4x Gigabit Ethernet (X102, X105, X108, X111)
3x USB 3.0 (X103, X106, X109)
3x USB 2.0 (X104, X107, X110)
2x DisplayPort (X112, X113)
RS232/422/485 serial port (X114)
Buttons with corresponding LEDs:
RSQ (Rescue)
PWR (Power)
LEDs:
GP1 to GP4 (general purpose LEDs)
THERM (thermal status)
DRIVE (SSD/HDD drive status)
M2 (M.2 card activity)
WD (Watchdog status)
Standard Baseboard - Onboard and System Expansion Capabilities:
up to 4x SATA and power connector (for internal or removable devices, depending on the configuration)
1x Mini PCIe x1 socket (J20, on the lower side of the baseboard)
3x M.2 (J13, J17 and J18; 2x B type, 1x M type)
1x PCIe x8 socket for expansion via riser cards
1x USB3.0 port for e.g. connection of USB dongles (J14)
MicroSIM and MicroSD card combo connector (J28)
CR2032 coin battery (J29)
Optional System Extension:
RS232/RS422 Port: via internal factory mounted and configured RS232/RS422 adapter module (X205)
CAN Port: via internal factory mounted CAN adapter module (X204)
DisplayPort or WideLink port (X203, X202; via corresponding internal factory mounted adapter modules)
Optional fan tray (not possible for KBox C-103-CFL-0)
Profibus, Profinet or Ethercat Fieldbus support: via internal factory mounted adapter module (X201, X206)
LTE: via internal factory mounted adapter module
WiFi: via corresponding internal factory mounted adapter module (X206)
Optional second 24 VDC power input (X201)
Optional GPIO module
The KBox C-103-CFL is a fanless system with a compact aluminum chassis with cooling fins which can be optionally
equipped with a fan tray for active cooling (KBox C-103-CFL-1/-2/-4 only!)
The rated voltage range of the mains can be found on the type label. The type label is located at the right side of the
device (Figure 21, pos. 9).
The KBox C-103-CFL is designed to be operated wall mounted inside a control cabinet, in
vertical position, except with the top side facing down.
When you power on the KBox C-103-CFL, make sure that the air exhaust openings on the top
side (Figure 23, pos. 12), the air intake openings on the bottom side (Figure 24, pos. 11) and
the cooling fins of the chassis (Figure 22, Figure 23 and Figure 24, pos. 6) are not obstructed
(covered) by any objects.
To provide sufficient heat dissipation via the cooling fins of the device, do not cover the
cooling fins of the KBox C-103-CFL. Do not place any objects on the device. When installing
the system, please observe the clearance recommendation (keep out area) in the subsection
8.2“Control Cabinet Mounting”; refer to the marked areas in Figure 46 to Figure 52.