background image

s30nmdl2sm-rev0614 

                                                 Model S30 Non-Metallic Page 12

TROUBLESHOOTING

Possible Symptoms:

• 

Pump will not cycle.

• 

Pump cycles, but produces no flow.

• 

Pump cycles, but flow rate is 

unsatisfactory.

• 

Pump cycle seems unbalanced.

• 

Pump cycle seems to produce 

excessive vibration.

What to Check: 

Excessive suction lift 

in system.

Corrective Action: 

For lifts exceeding 

20 feet (6 meters), filling the pumping 

chambers with liquid will prime the 

pump in most cases.

What to Check: 

Excessive flooded 

suction in system.

Corrective Action: 

For flooded 

conditions exceeding 10 feet (3 meters) 

of liquid, install a back pressure device.

What to Check: 

System head exceeds 

air supply pressure.

Corrective Action: 

Increase the 

inlet air pressure to the pump. Most 

diaphragm pumps are designed for 1:1 

pressure ratio at zero flow.

What to Check: 

Air supply pressure or 

volume exceeds system head.

Corrective Action: 

Decrease inlet 

air pressure and volume to the 

pump as calculated on the published 

PERFORMANCE CURVE. Pump is 

cavitating the fluid by fast cycling.

What to Check: 

Undersized suction 

line.

Corrective Action: 

Meet or exceed 

pump connection recommendations 

shown on the DIMENSIONAL 

DRAWING.

What to Check: 

Restricted or 

undersized air line.

Corrective Action: 

Install a larger 

air line and connection. Refer to air 

inlet recommendations shown in your 

pump’s SERVICE MANUAL.

What to Check: 

Check ESADS+Plus, 

the Externally Serviceable Air 

Distribution System of the pump.

Corrective Action: 

Disassemble and 

inspect the main air distribution valve, 

pilot valve and pilot valve actuators. 

Refer to the parts drawing and air valve 

section of the SERVICE MANUAL. 

Check for clogged discharge or closed 

valve before reassembly.

What to Check: 

Rigid pipe connections 

to pump.

Corrective Action: 

Install flexible 

connectors and a  surge suppressor.

What to Check: 

Blocked air exhaust 

muffler.

Corrective Action: 

Remove  muffler 

screen, clean or de-ice and reinstall. 

Refer to the Air Exhaust section of your 

pump SERVICE MANUAL.

What to Check: 

Pumped  fluid  in  air 

exhaust muffler.

Corrective Action: 

Disassemble 

pump chambers. Inspect for diaphragm 

rupture or loose diaphragm plate 

assembly. Refer to the Diaphragm 

Replacement section of your pump 

SERVICE MANUAL.

What to Check: 

Suction side air 

leakage or air in product.

Corrective Action: 

Visually inspect 

all suction side gaskets and pipe 

connections.

What to Check: 

Obstructed check 

valve.

Corrective Action: 

Disassemble the 

wet end of the pump and manually 

dislodge obstruction in the check valve 

pocket. Refer to the Check Valve 

section of the pump SERVICE MANUAL 

for disassembly instructions.

What to Check: 

Worn or misaligned 

check valve or check valve seat.

Corrective Action: 

Inspect check 

valves and seats for wear and proper 

seating. Replace if necessary. Refer 

to Check Valve section of the pump 

SERVICE MANUAL for disassembly 

instructions.

What to Check: 

Blocked suction line.

Corrective Action: 

Remove  or  flush 

obstruction. Check and clear all suction 

screens and strainers.

What to Check: 

Blocked discharge 

line.

Corrective Action: 

Check for 

obstruction or closed discharge line 

valves.

What to Check: 

Blocked pumping 

chamber.

Corrective Action: 

Disassemble 

and inspect the wetted chambers 

of the pump. Remove or flush any 

obstructions. Refer to the pump 

SERVICE MANUAL for disassembly 

instructions.

What to Check: 

Entrained air or vapor 

lock in one or both pumping chambers.

Corrective Action: 

Purge chambers 

through tapped chamber vent plugs. 

PURGING THE CHAMBERS OF 

AIR CAN BE DANGEROUS! Contact 

the Warren Rupp Technical Services 

Department before performing this 

procedure. A model with top-ported 

discharge will reduce or eliminate 

problems with entrained air.

If your pump continues to perform 

below your expectations, contact your 

local Warren Rupp Distributor or factory 

Technical Services Group for a service 

evaluation.

WARRANTY

Refer to the enclosed Warren Rupp 

Warranty Certificate.

Содержание S30

Страница 1: ...st 21 Air Distribution Valve with Stroke Indicator Servicing 22 Solenoid Shifted Air Valve Drawing 23 Solenoid Shifted Air Valve Parts List 23 Solenoid Shifted Air Distribution Valve Option 24 Pilot Valve Assembly Drawing 25 Pilot Valve Assembly Parts List 25 Pilot Valve Servicing 26 Diaphragm Service Drawing Non Overlay 27 Diaphragm Service Drawing with Overlay 27 Diaphragm Servicing 28 Overlay D...

Страница 2: ......

Страница 3: ...ACITY 0 to 238 US gallons per minute 0 to 901 liters per minute AIR VALVE No lube no stall design SOLIDS HANDLING Up to 71 in 18mm HEADS UP TO 100 psi or 231 ft of water 7 bar or 70 meters DISPLACEMENT STROKE 9 US gallon 3 41 liter CAUTION Maximum Operating Temperature Limit is 180 F for Polypropylene and 250 F for PVDF Models Air Inlet Side View Air Exhaust Side View Quality System ISO 9001 Certi...

Страница 4: ...earance Air Valve with Sound Dampening Muffler 5 Expanded Clearance Air Valve w Mesh Muffler S30 Non Metallic Design Level 2 Ball Valve Explanation of Pump Nomenclature Kit Options 00 None P0 10 30VDC Pulse Output Kit P1 Intrinsically Safe 5 30VDC 110 120VAC 220 240VAC Pulse Output Kit P2 110 120 or 220 240VAC Pulse Output Kit E0 Solenoid Kit with 24VDC Coil E1 Solenoid Kit with 24VDC Explosion Pr...

Страница 5: ...Y U S Gallons per minute Liters per minute BAR PSI HEAD NPSHR METERS FEET MODEL S30 Non Metallic Performance Curve Performance based on the following elastomer fitted pump flooded suction water at ambient conditions The use of other materials and varying hydraulic conditions may result in deviations in excess of 5 40 PSI 2 72 Bar 20 PSI 1 36 Bar 80 PSI 5 44 Bar Air Inlet Pressure 100 PSI 6 8 Bar 6...

Страница 6: ...NGE CONFIGURATION 3 4 DIA 4 HOLES EQUALLY SPACED ON A 6 DIA BOLT CHANGE STANDARD INTEGRAL MUFFLER 1 NPT EXHAUST PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN SUBMERGED APPLICATIONS Dimensions S30 Non Metallic Dimensions in Inches Dimensional tolerance 1 8 Note Porting Flanges are also available with PN10 80mm DIN bolting configuration Note Dimensions A is from the vertical center line ...

Страница 7: ...PLACES BOTTOM VIEW SIDE VIEW FRONT VIEW SUCTION PORT 3 STANDARAD 125 FLANGE CONFIGURATION 3 4 DIA 4 HOLES EQUALLY SPACED ON A 6 DIA BOLT CHANGE STANDARD INTEGRAL MUFFLER 1 NPT EXHAUST PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN SUBMERGED APPLICATIONS AIR INLET 3 4 NPT Note Porting Flanges are also available with PN10 80mm DIN bolting configuration Note Dimensions A is from the vertic...

Страница 8: ...IEW SUCTION PORT 3 STANDARAD 125 FLANGE CONFIGURATION 3 4 DIA 4 HOLES EQUALLY SPACED ON A 6 DIA BOLT CHANGE STANDARD INTEGRAL MUFFLER 1 NPT EXHAUST PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN SUBMERGED APPLICATIONS Dimension Standard Pump A B 6 9 16 6 9 16 Pulse Output Kit Sound Dampening Muffler Mesh Muffler 12 11 16 12 11 16 13 3 4 22 9 32 8 13 16 14 15 16 Note Porting Flanges are ...

Страница 9: ...3 STANDARAD 125 FLANGE CONFIGURATION 3 4 DIA 4 HOLES EQUALLY SPACED ON A 6 DIA BOLT CHANGE STANDARD INTEGRAL MUFFLER 1 NPT EXHAUST PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR IN SUBMERGED APPLICATIONS Metric Dimensions S30 Non Metallic with Spill Containment Dimensions in Millimeters Dimensional tolerance 3mm Dimension Standard Pump A B 167mm 167mm Pulse Output Kit 322mm 322mm Sound Dam...

Страница 10: ...ible hose reduces vibration and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow AIR SUPPLY Air supply pressure cannot exceed 100 psi 7 bar Connect the pump air inlet to an air supply of sufficient capacity and pressure required for desired performance When the air supply line is solid piping use a short length of flexible hose not less than 13mm i...

Страница 11: ...51 000 Filter Regulator Air Dryer Available from Warren Rupp CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure INSTALLATION GUIDE Top Discharge Ball Valve Unit 2 Surge Suppressor Limited to 100 psi ...

Страница 12: ...g and all other openings and connections Be certain the air supply is locked out or made non operational so that it cannot be started while work is being done on the pump Be certain that approved eye protection and protective clothing are worn all times in the vicinity of the pump Failure to follow these recommendations may result in serious injury or death WARNING WARNING In the event of diaphrag...

Страница 13: ...ED 361 Nitrile 363 FKM Fluorocarbon Color coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 405 Cellulose Fibre 408 Cork and Neoprene 425 Compressed Fibre 426 B...

Страница 14: ...orrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Check Pumped fluid in air exhaust muffler Corrective Action Disassemble pump chambers Inspect for diaphragm rupture or loose diaphragm plate assembly Refer to the Diaphragm Replacement section of your pump SERVICE MANUAL What to Check Suction side air leakage or...

Страница 15: ... Seals 476 140 654 WETTED END KIT Santoprene Diaphragms PTFE Overlay Diaphragms TFE Balls and TFE Seals 476 143 354 WETTED END KIT for Polypropylene Spill Containment Santoprene Diaphragms PTFE Overlay Diaphragms PTFE Pumping Diaphragms PTFE Balls and PTFE Seals 476 143 655 WETTED END KIT for PVDF Spill Containment Santoprene Diaphragms PTFE Overlay Diaphragms PTFE Pumping Diaphragms PTFE Balls an...

Страница 16: ...mber Outer 2 16 196 152 307 Chamber Inner 2 196 152 309 Chamber Inner 2 196 152 332 Chamber Inner 2 17 286 077 354 Diaphragm 2 286 077 357 Diaphragm 2 18 286 078 600 Diaphragm Overlay 2 19 312 103 520 Elbow 4 312 103 552 Elbow 4 20 360 090 360 Gasket Air Inlet 1 21 360 091 360 Gasket Inner Chamber 2 22 360 092 360 Gasket Pilot Valve 1 23 360 093 360 Gasket Main Air Valve 1 24 518 133 520 Manifold ...

Страница 17: ...x HD 5 8 11 x 4 00 4 45 196 156 552 Chamber Spill Containment 2 196 156 600 Chamber Spill Containment 2 46 286 079 600 Diaphragm Pumping 2 47 518 135 520 Manifold 2 518 135 520E Manifold 80mm DIN 2 518 135 552 Manifold 2 518 135 552E Manifold 80mm DIN 2 48 538 022 110 Nipple Pipe 4 538 022 308 Nipple Pipe 4 49 560 078 611 O Ring 8 50 618 003 110 Plug Pipe 4 618 003 308 Plug Pipe 4 51 618 025 110 P...

Страница 18: ...Apply air pressure to the air distribution valve Install safety clip item 1 F into the smaller unthreaded hole in one end cap This locks the valve spool to one side keeping the pump from shifting 5 Face the side of the pump with the installed safety clip If the safety clip is installed in the top end cap fill the left spill containment chamber If the safety clip is installed on the bottom end cap ...

Страница 19: ...6 156 552 Chamber Spill Containment 2 196 156 600 Chamber Spill Containment 2 46 286 080 354 Diaphragm Pumping 2 47 518 135 520 Manifold Spill Containment 2 518 135 520E Manifold 80mm DIN 2 518 135 552 Manifold Spill Containment 2 518 135 552E Manifold 80mm DIN 2 48 538 022 110 Pipe Nipple 4 538 022 308 Pipe Nipple 4 49 560 078 611 O ring 8 50 618 003 110 Plug Pipe 4 618 003 308 Plug Pipe 4 51 618...

Страница 20: ...y air pressure to the air distribution valve Install safety clip item 1 F into the smaller unthreaded hole in one end cap This locks the valve spool to one side keeping the pump from shifting 5 Face the side of the pump with the installed safety clip If the safety clip is installed in the top end cap fill the left Spill Containment chamber If the safety clip is installed on the bottom end cap fill...

Страница 21: ...675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self tapping 4 For pumps equipped with PTFE Coated Hardware 1 031 140 002 Air Valve Assembly 1 Includes all items used on 031 140 000 except 1 J 710 015 308 Screw Self tapping 4 1 H 675 044 308 Ring Retaining 2 For pumps equipped with PTFE coated hardware option 1 031 141 000 Air Valve Assembly 1 Includes all items used on 031 140 000 minus items ...

Страница 22: ...hes or other contaminates Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one end cap item 1 E with an o ring item 1 G and one bumper item 1 C into one end of the air valve body item 1 B Install one retaining ring item 1 H into the groove on the same end Remove the new sleeve an spool set item 1 A...

Страница 23: ...360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self Tapping 4 1 K 210 008 330 Clip Safety 1 1 M 560 029 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 1 H 675 044 308 Ring Retaining 2 includes all other items on 031 146 000 above For Pumps with Alternate Mesh Sound Dampening Mufflers or Piped Exhaust 1 0...

Страница 24: ...ve the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one bumper item 1 C and one end cap item 1 E with an o ring item 1 G into one end of the air valve body item 1 B Install one retaining ring item 1 H into the groove on the same end Insert the safety clip item 1 K through the small unthreaded hole in the ...

Страница 25: ...DC 1 219 002 000 Solenoid Coil 120VAC 1 219 003 000 Solenoid Coil 240VAC 1 59 241 001 000 Connector conduit 1 60 170 061 115 Capscrew Hex HD 3 8 16 x 1 75 4 61 618 052 506 Plug 2 For Explosion Proof Solenoid Valve 58 219 009 001 Solenoid Coil 120VAC 60 Hz 1 219 009 002 Solenoid Coil 240VAC 60 HZ 1 219 009 003 Solenoid Coil 12VDC 1 219 009 004 Solenoid Coil 24VDC 1 219 009 005 Solenoid Coil 110VAC ...

Страница 26: ...o cycle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric power is turned off the solenoid shifts and the pressurized chamber is exhausted while the other chamber is pressurized By alternately applying and removing power to the solenoid the pump cycles much l...

Страница 27: ... LIST ITEM PART NUMBER DESCRIPTION QTY 2 095 089 000 Pilot Valve Assembly 1 2 A 095 081 551 Body Pilot Valve 1 2 B 135 033 506 Bushing 2 2 C 675 055 115 Ring Retaining 2 2 D 770 049 175 Spacer 5 2 E 917 001 374 Wiper 6 2 F 775 033 506 Spool Pilot 1 Pilot Valve Assembly Drawing ...

Страница 28: ...rs and spacers until they are against the installed retaining ring in the opposite end of the pilot valve body Install the remaining bushing making sure the step side faces the wiper Install the remaining retaining ring using clip ring pliers Apply a light coating of grease to the inner diameter of each wiper Also apply a light coating of grease to the outer diameter of the pilot valve spool and g...

Страница 29: ...s30nmdl2sm rev0614 Model S30 Non Metallic Page 27 Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay 32 25 15 13 6 28 17 16 29 9 14 24 24 32 25 15 13 6 28 17 29 9 14 24 24 ...

Страница 30: ... compensate for stress relaxation in the clamped assembly Step 5 Installing the diaphragm assemblies to the pump Make sure the bumper item 6 is installed over the diaphragm rod Threadthestudoftheonediaphragm assembly clockwise into the tapped hole at the end of the diaphragm rod item 33 until the inner diaphragm plate is flush to the end of the rod Insert rod into pump Align the bolt holes in the ...

Страница 31: ...t source is at a higher level than the pump flooded suction condition pipe the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right CONVERTING THE PUMP FOR PIPING THE EXHAUST AIR The following steps are necessary to convert the pump to pipe the exhaust air away from the pump Use a 8 Torx or flat screwdriver to remove the six self tapping screws item 1 J Re...

Страница 32: ... abrasive wear or embedded materials Replace as needed Inspect the check balls items 3 for wear abrasion or cuts on the spherical surface The check valve seats items 38 should be inspected for cuts abrasive wear or embedded material on the surfaces of both the external and internal chamfers The spherical surface of the check balls must seat flush to the surface of the inner chamfer on the check va...

Страница 33: ...l2sm rev0614 Model S30 Non Metallic Page 31 Dual Port Option Drawing 3 ANSI STYLE FLANGE CONNECTION FOUR ø 75 HOLES ON A ø6 00 BOLT CIRCLE 3 ANSI STYLE FLANGE CONNECTION FOUR ø 75 HOLES ON A ø6 00 BOLT CIRCLE ...

Страница 34: ...he Dual Porting Drawing Single porting of the suction and dual porting of the pump discharge To convert the pump from the standard single suction and single discharge porting configuration to a dual discharge porting arrangement remove the only the discharge manifolds spacers and manifold seals Position the discharge elbows in the desired direction at 90 increments See arrows and optional position...

Страница 35: ...0 12 32VDC To install electronic leak detectors remove the bottom NPT pipe plug on the visual sight tube item 52 Insert leak detector into the pipe tee item 56 LEAK DETECTION OPTION MECHANICAL Follow instructions found elsewhere in this manual Filling the Spill Containment Chambers when installing leak detectors Mechanical Leak Detector Installation Kit 031 023 110 To install mechanical leak detec...

Страница 36: ...e Stroke Counter Batch Controller or user control devices such as a PLC The Pulse Output Kits mount directly onto the Muffler Cap on theAir Distribution Valve Assembly or onto the air valve and senses each stroke of the main spool Consult the factory for further information and availability Pulse Output Kit Drawing Pulse Output Kits 475 244 001 10 30 VDC 475 244 002 110 220 VAC 475 244 003 10 30VD...

Страница 37: ...0 12 32VDC To install electronic leak detectors remove the bottom NPT pipe plug on the visual sight tube item 52 Insert leak detector into the pipe tee item 56 LEAK DETECTION OPTION MECHANICAL Follow instructions found elsewhere in this manual Filling the Spill Containment Chambers when installing leak detectors Mechanical Leak Detector Installation Kit 031 023 110 To install mechanical leak detec...

Страница 38: ... hold it in place OPTION 1 530 027 000 Sound Dampening Muffler screws directly into the Air Valve body This muffler is equipped with a porous plastic element OPTION 2 530 010 000 Mesh Muffler screws directly into the Air Valve Body This muffler is equipped with a metal element OPTION 6 530 033 000 Metal Muffler screws directly into the Air Body Option 1 and 2 Option 6 Option 0 ...

Страница 39: ...A Certifies that Air Operated Double Diaphragm Pump Series HDB HDF M Non Metallic S Non Metallic M Metallic S Metallic T Series G Series U Series EH and SH High Pressure RS Series W Series SMA and SPA Submersibles and Tranquilizer Surge Suppressors comply with the European Community Directive 2006 42 EC on Machinery according to Annex VIII This product has used Harmonized Standard EN809 1998 A1 20...

Отзывы: