6
ERROR ROUTINE
If the ENTER button is activated at the "EROR" prompt the VMC will enter in the error
routine. If no errors have occurred since the last error reset the display will show a
"NONE" message. If an error has been detected since the last error reset the display will
show the first summary level error code that has occurred, such as "COLJ", which would
indicate a column jam error. Using the UP or DOWN buttons will cycle through the various
summary level error.
Activation of the HOME button while summary level error code is displayed will return the
VMC to the "EROR" prompt.
Activation of the HOME button at "EROR" prompt returns the VMC to the normal mode
door open state.
The most common errors are :
VEND
Vend Mechanism on master
VENDS
Vend Mechanism on slave
CTRL
Control error
SELS
Selection Switch
CHAR
Changer
BVAL
Bill Validator
DETEC
Optical detector
RFRG
Temperature error
MASTER VEND ERROR ROUTINE
If the ENTER button is activated at the "VEND" prompt the VMC will display a "CJXX"
message where XX indicates the columns that have been detected as being jammed.
Using the UP and DOWN buttons will cycle through all jammed columns. If the ENTER
button is pressed and held for two seconds during the display of any error code, that code
will be cleared.
After clearing, VMC will display the next existing column jam error, or "NONE" if no other
error.
Activation of HOME button will return the VMC to the code level at the "EROR" message.
SLAVE VEND ERROR ROUTINE (ONLY WHEN SLAVE IS ENABLED)
The function is the similar to the vend error routine, the only difference is that the error
showed is "CJXS", and it’s related to the slave machine.
ATTENTION: The vend errors (both for master and slave) are cancelled
automatically when the master door is closed.