CONFY
C01 COINAGE KEYPAD ACTIVATION (COINAGE MDB)
C01 = 0 Disabled
C01 = 1 Enabled
C02 LOW CHANGE EQUATION (MDB MODE)
This parameter defines the exact change equation. The combination of the empty states
assume the exact change state
A is the lowest coin value reported in the tubes
E is the highest coin value reported in the tubes
If the tubes are empty according to these equations the
CORRECT CHANGE LED is ON
0 : TUBE A and TUBE B and TUBE C and TUBE D
1 : TUBE A or TUBE B or TUBE C
2 : TUBE A only
3 : TUBE B only
4 : TUBE C only
5 : TUBE D only
6 : TUBE B or TUBE C or TUBE D
7 : TUBE A and TUBE B or TUBE C
8 : TUBE A and TUBE B or TUBE D
9 : TUBE A and TUBE C or TUBE D
10 : TUBE B and TUBE C or TUBE D
11 : TUBE A and TUBE D or TUBE C
12 : TUBE B and TUBE D or TUBE A
13 : TUBE A or TUBE C
14 : TUBE A or TUBE B and TUBE C
15 : TUBE A or TUBE B
16 : TUBE A and TUBE B and TUBE C and TUBE D and TUBE E
17 : TUBE A or TUBE B or TUBE C or TUBE D or TUBE E
ATTENTION:
When using Executive please be
aware to set "CONFY" parameter
C2 to 0 otherwise machine is
working in "Price holding" mode.