Instructions for programming
BB01 Board functions
16
© SandenVendo
4.1.2 Vend Mechanism error routine
If the ENTER button is activated at the "
VEND
" prompt the VMC will display a "
HSXX
"
message where "
XX
" indicates the first column that has been detected with a home sensor
error.
Using the UP or DOWN buttons will cycle through all jammed columns. If the ENTER
button is pressed and held for two seconds during the display of any error code, that code
will be cleared.
After clearing VMC will display the next existing column jam error, or "
NONE
" if no other
error.
Activation of HOME button will return the VMC to the code level at the "
EROR
" message.
4.1.3 Door Switch error routine
If the ENTER button is activated at the
"DOOR"
prompt the VMC will display a
"DS"
message indicating a door switch error was detected (door open for more than one hour).
If the ENTER button is pressed and held for two seconds during the display of any error
code, that code will be cleared.
After clearing VMC will display the next existing error or
"NONE"
if no other error.
Activation of HOME button will return the VMC to the code level at the
"EROR"
message.
4.1.4 Selection Switch error routine
If the ENTER button is activated at the "
SELS
" prompt the VMC will display a "
SSXX
"
message where "
XX
" indicates the first selection switch error (switch always close).
Using the UP and DOWN buttons will cycle through all selection switch error. If the ENTER
button is pressed and held for two seconds during the display of any error code , that code
will be cleared.
After clearing VMC will display the next existing error, or "
NONE
" if no other error.
Activation of HOME button will return the VMC to the code level at the "
EROR
" message.
4.1.5 Changer error routine
If the ENTER button is activated at the "
CHAR
" prompt the VMC will display a "
CC
"
message indicating a changer communication error a "
TS
" message indicating a tube
sensor error, an "
IC
" message indicating an Inlet chute blocked error (no coins sensed in
the acceptor for a supplier pre-determined number of hours, a "
TJ
" message indicating a
tube jam error, or a "
CRCH
" message indicating a changer ROM checksum error. "
EE
"
message indicating excessive escrow attempts (escrow to vends greater than a pre-
determined supplier standard), and "
NJ
" message indicating a coin jam (sensed and
reported by coin mechanism), "
LA
" message indicating a low acceptance rate , “
DIS
”
changer disconnect “
ROUT
” coin rout error. Using the UP or DOWN buttons will cycle
through all acceptor errors. If the ENTER button is pressed and held for two seconds
during the display of any error code , that code will be cleared.
After clearing VMC will display the next existing error, or "
NONE
" if no other error.
Activation of BACK button will return the VMC to the code level at the "
EROR
" message.
Содержание Vendo BB01
Страница 13: ...Instructions for programming BB01 Board functions 11 SandenVendo...
Страница 14: ...Instructions for programming BB01 Board functions 12 SandenVendo...
Страница 33: ...31 SandenVendo...
Страница 34: ...32 SandenVendo 6 28 10 2014 Update Address page Update CONF C11 C12 22 23 Update Annexe Software BB01 30...