4. Alignment and Troubleshooting
b) Check the thermistor resistance.
-
Check the thermistor resistance with DVM. And then, check if the measured value is normal with
the table below.
Temperature (
℃
)
Resistance Range (K
Ω
)
0 ~ 5
657 ~ 1200
5 ~ 10
539 ~ 965
10 ~ 15
444 ~ 782
15 ~ 20
368 ~ 637
20 ~ 25
307 ~ 522
25 ~ 30
257 ~ 430
30 ~ 35
217 ~ 357
35 ~ 40
183 ~ 297
•
Check the Heater.
Check the fuser lamp terminal resistance with DVM. (Normal range : 5 ~ 10
Ω
)
4-53