- 22 -
Main relay
abnormal
18E
If AC power signal is detected for longer than 4sec even after
connection of power plug or after opening of the relay by power
off, this error will occur.
Unplug the
power plug, and
PCB needs to
repair.
Switch
(button)
abnormal
12E
If power switch is continuously being pressed for 12sec after
power-on, this error will occur.
Power Off
14E
If a button on the control panel is continuously being pressed
for 30sec.
No pressing of a
button longer
than 1sec will
release this error.
8888
If there is no press of any button for 10min after power-on or
changing course before entering an operation, this error will
occur.
Power will be
automatically off
after 5sec.
Door
abnormal
dE
If door is open for longer than 1sec at the time of entering or
during an operation, this error will occur.
Close the door
and press
START button
again.
dE1
If the lock or unlock function of door doesn't work after 3time of
trial, this error will occur.
Power Off
dE2
This error occurs to protect a coil in the locking apparatus
against frequent usage of lock and unlock function of door.
Automatically
released after
25sec.
Communic
ation
abnormal
13E
If a communication to MCU on the control panel is abnormal for
longer than 2sec, it functions to reset MCU to 20mSec and to
retry the communication. Abnormal communication for longer
than 6sec will make this error.
If there is no
abnormal
communication
for longer than
1sec, it is
automatically
released.
Excessive
water
level/water
leakage
0F
If less than 20.48kHz of frequency of water level sensor is
continuously kept longer than 10sec, this error will occur.
(caused by abnormal increase of water level due to breakdown
of feed valve)
Appearance: It functions to operate drain pump to the frequency
level of 23.30kHz in 20sec-On/4sec-Off.
Power Off
11E
If higher than 24.70kHz of frequency of water level sensor
during washing and rinse, this error will occur.
(caused by water leakage at pump, hose, drum tub, etc.)
Power Off
Fan motor
abnormal
F
If excessive current signal due to restriction of fan motor is
detected for longer than 40sec, this error will occur.
Power Off
Water
Feed
abnormal
4E
If the feed water for washing or rinse doesn't reach the terminal
level of water supply after 20min, this error will occur.
Start button
4Ed
If higher than 70°C is continuously detected for longer than
8sec at temperature sensor of drying duct during drying, this
error will occur.
Start button
EC
If higher than 50°C of water temperature is detected at the time
of water feed after selection of WOOL and LINGERIE
COURSES, this error functions to prevent damage from such a
high water temperature.
Power Off
Water
Drain
abnormal
5E
If the water level frequency doesn't reach 24.70kHz after 15min
during the water drain, or if the water level frequency of less
than 23.84kHz is detected for longer than 20sec during
dehydration or drying, this error will occur. (caused by foreign
matters in the drain pump or the breakdown)
Start button