background image

Door Lock Check

 

Test 1

 

Test 2

 

Connector CN Pin 3 (Blk) and RY1 Pin 2 (Blue)

 

When Door is Unlocked 6VAC     
When Door is Locked 0VAC

 

N/A

 

Door Switch Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 6 (Wht) and RY1 Pin 2(Blu)

 

48

  Door Closed, 

 Door Open

 

 

A/C Power Check

 

Test 1

 

Test 2

 

Connector CN 2 Pin 1 (Blu) and RY1 Pin 1 (Wht) 
Connector CN 2 Pin 1 (Blu) and RY1 Pin 2 (Blu) 

Power Off 120VAC                         
Power Off 0VAC - Power On 120VAC

 

N/A 

Drain Motor Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 4 (Gry) and RY1 Pin 2 (Blu)

 

120VAC with the pump On and 0VAC 
with the pump off

 

Power Off, the resistance should be 
14

 

Water Valve Check

 

Test 1

 

Test 2

 

Connector CN2 Pin  (Blu) to CN5 Pin 3 (Pink), Pin 
2 (Red) , Pin 1 (Blue)

 

120VAC with the Valve On and 0VAC 
with the Valve off

 

Power Off, valve resistance is from 
1202

 - 1245

 

Error Type  

Error Mode  

Details  

LED LCD 

                                                         
Water Level Sensor 

               
LE       

 

Check the Hose where the sensor is connected, may be loose, 
pinched, damaged or clogged. Also check the sensor it may be 
disconnected or defective. The Main PCB may also be defective  

                                                 
Motor Drive  Error or 
Hall Sensor error  

 

         
3E 

 

Check the  motor drive connector, it may be loose. The hall sensor 
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose 
or damaged. The drum might be overloaded from too many 
clothes or the relay or PCB  might be defective.      

 

E3 

bE 
25 

                                              
Water Supply 

Error 

                        
nF   

 

Check the water valve wiring harness. 

Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly. 

Check for reversed fill hoses 

Check water temperature, if sensed as higher than 50 

˚

C in the 

Wool or Lingerie cycle it will create error. 

Check the relays, if they operate correctly replace the Main PCB. 

Fill Hoses Reversed  nF1 

 

Correct Hot/Cold hose connections 

System Error 

SF1 
SF2  
SF3 

 

Replace PCB

 

Water Level Sensor 

1E 

 

Water Level Sensor Trouble, Signal out of range 

Содержание WF210ANW/XAA

Страница 1: ... Main PCB input Tests enter Service Mode press the Extra Rinse key until the display shows ln 1 Turn the Dial CCW to Normal Temperature will be dis played in Celsius 2 Turn the Dial CCW to Heavy Duty Temperature will be dis played in Fahrenheit 3 Turn the Dial CCW to Perm Press The door switch status will be displayed CL if Closed OP if Open 4 Turn the Dial CCW to Rinse Spin The door lock Switch s...

Страница 2: ...RY1 ...

Страница 3: ...he volt age change Power On 0Vdc or 3 75Vdc N A Motor Check Test 1 Test 2 Connector CN9 Pin 1 Blue Pin 2 White and Pin 3 Red Power Off 11 5Ω across Pins 1 2 Pins 1 3 Pins 2 3 N A CN1 1 Motor Pwr U Phase Blu 2 Motor Pwr V Phase Wht 3 Motor Pwr W Phase Red CN5 1 Main Valve Blu 2 Hot Valve Red 3 Bleach Valve Pnk 4 Drain Pump Gry 6 Door Lock Wht CN8 Hull Sensor 1 5 vdc Pnk 2 Sensor Signal Red 3 Sensor...

Страница 4: ...here the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign ob ject inside the motor or motor damage The stator might be loose or damag...

Страница 5: ...re If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are ...

Страница 6: ...ons for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the load or remove a few items Press start to continue and complete the wash cycle Foaming Detected SUdS Sd SUd This occurs when too much foaming is detected It is also displayed while...

Страница 7: ...nsumer of proper detergent usage It is normal for some water to remain in Deter gent Drawer after it completes washing Bleach is usually flushed out into the tub at the beginning of the washing Also its compart ment is washed again during the following rinse cycle removing any remnants To unlock the door if washer is stuck in the door locked mode Remove top remove console remove screws for front p...