background image

Water valve connections for the Detergent Drawer

 

Items Packed With Washer 

BOLT-SPANER (10-13mm Wrench) DC60-40146A 
ASSY HOSE WATER  Cold DC97-15648A       
ASSY HOSE WATER  Hot DC97-15648B           
CAP-FIXER DC67-00307A                               
HOSE-HANGER DC62-10278A 

 

When using non-HE detergents, or using too much deter-
gent for the water hardness and soil level of the clothing, 
over sudsing will occur. When this happens there will be 
leaks out of the detergent drawer and door. Please advise 
consumer of proper detergent usage.

 

It is normal for some water to remain in Deter-
gent Drawer after it completes washing.  
Bleach is usually flushed out into the tub at the 
beginning of the washing. Also, its compart-
ment is washed again during the following 
rinse cycle, removing any remnants. 

 

To unlock the door 

if washer is stuck in the door 

locked mode. 

Remove top, remove console, remove screws for 
front panel, pull panel forward. 

Picture “A” pull bottom of plastic cover away from 
front until it pops off. 

Picture “B” pull  down on plastic lever to release 
lock. 

Remove lock assembly to replace plastic cover.

 

 

 

NOTE: Tee 
moved to 
Main Valve 
hose on later 
production. 

Содержание WF210ANW/XAA

Страница 1: ... Main PCB input Tests enter Service Mode press the Extra Rinse key until the display shows ln 1 Turn the Dial CCW to Normal Temperature will be dis played in Celsius 2 Turn the Dial CCW to Heavy Duty Temperature will be dis played in Fahrenheit 3 Turn the Dial CCW to Perm Press The door switch status will be displayed CL if Closed OP if Open 4 Turn the Dial CCW to Rinse Spin The door lock Switch s...

Страница 2: ...RY1 ...

Страница 3: ...he volt age change Power On 0Vdc or 3 75Vdc N A Motor Check Test 1 Test 2 Connector CN9 Pin 1 Blue Pin 2 White and Pin 3 Red Power Off 11 5Ω across Pins 1 2 Pins 1 3 Pins 2 3 N A CN1 1 Motor Pwr U Phase Blu 2 Motor Pwr V Phase Wht 3 Motor Pwr W Phase Red CN5 1 Main Valve Blu 2 Hot Valve Red 3 Bleach Valve Pnk 4 Drain Pump Gry 6 Door Lock Wht CN8 Hull Sensor 1 5 vdc Pnk 2 Sensor Signal Red 3 Sensor...

Страница 4: ...here the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign ob ject inside the motor or motor damage The stator might be loose or damag...

Страница 5: ...re If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are ...

Страница 6: ...ons for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the load or remove a few items Press start to continue and complete the wash cycle Foaming Detected SUdS Sd SUd This occurs when too much foaming is detected It is also displayed while...

Страница 7: ...nsumer of proper detergent usage It is normal for some water to remain in Deter gent Drawer after it completes washing Bleach is usually flushed out into the tub at the beginning of the washing Also its compart ment is washed again during the following rinse cycle removing any remnants To unlock the door if washer is stuck in the door locked mode Remove top remove console remove screws for front p...

Отзывы: