When installing a washer and dryer on the first, or second
floor, do not exceed this leg adjustment height for stability.
Error Type
Error Mode
Details
LED LCD
Heater Error
Hr
36
(Heater
Relay)
This can be a short or a wire disconnected to the heater circuit. This
can also be problem with the tub contacting the heater or if the wa-
ter in the tub is frozen or there is no water. The error is triggered by
temperatures above 145C. If the heater has no error, this occurs
because of a PBA relay malfunction. Check the wiring harness to
the heater.
An Hr error occurs if the steam heater, is faulty, replace it.
9E1
EMC Filter issue or a noise spike from an external device
Overflow error
OE
1E
Water is supplied continually because the water level detection
does not work. - Verify the drain is working properly, the water level
detection does not work and water is supplied continually. Verify the
water valves shut off fully. Finally check the water level sensor.
Temperature
Sensor Error
29
The washing heater temperature sensor in the tub has an error.
Check the connections for the washing heater temperature sensor
connector.
Unbalance
Error
dC
10
Check the type of laundry. Check whether it may cause an unbal-
anced situation.- Educate the consumer in this case, to press
pause, reposition the load or remove a few items. Press start to
continue and complete the wash cycle.
Foaming
Detected
SUdS
Sd
SUd
This occurs when too much foaming is detected. It is also displayed
while foaming is removed. When the removal is finished, the normal
cycle proceeds. (This is one of the normal operations. It is an error
for preventing non-sensing faults.)
Check whether the washing machine is level to the floor with respect to the original position of the washing machine prior
to service. Doing this now will reduce the need for a redo call and customer dissatisfaction.
✔ Vibrations can shorten the lifetime of the product.
Silver Care Kit
(Silver Care
PCB) Failure.
7E
Check Silver Care PCB ,Main PCB & Wire-harness
Mems or Har- 8E
Check MEMS PCB ,Main PCB & Wire-harness
Location considerations
Do not install your washer in areas
where water may freeze, since
your washer will always maintain
some water in its water valve,
pump, and hose areas. This can
cause damage the belts, the
pump, hoses and other compo-
nents.
Operating temperature
should be above 60°F/16°C.