background image

When installing a washer and dryer on the first, or second 
floor, do not exceed this leg adjustment height for stability.

 

Error Type  

Error Mode  

Details  

LED LCD 

                          
Heater Error  

                           
Hr           
36 

(Heater 

Relay)  

 

This can be a short or a wire disconnected to the heater circuit. This 
can also be problem with the tub contacting the heater or if the wa-
ter in the tub is frozen or there is no water. The error is triggered by 
temperatures above 145C. If the heater has no error, this occurs 
because of a PBA relay malfunction. Check the wiring harness to 
the heater.   

An Hr error occurs if the steam heater, is faulty, replace it. 

 

9E1 

 

EMC Filter issue or a noise spike from an external device 

                      
Overflow error 

                         
OE            
1E 

 

Water is supplied continually because the water level detection 
does not work. - Verify the drain is working properly, the water level 
detection does not work and water is supplied continually. Verify the 
water valves shut off fully. Finally check the water level sensor. 

                             
Temperature 
Sensor Error 

29 

 

The washing heater temperature sensor in the tub has an error. 
Check the connections for the washing heater temperature sensor 
connector. 

 

                   
Unbalance 

Error 

                         
dC           
10 

 

Check the type of laundry. Check whether it may cause an unbal-
anced situation.- Educate the consumer in this case, to press 
pause, reposition the load or remove a few items. Press start to 
continue and complete the wash cycle. 

                         
Foaming      
Detected 

                     
SUdS     
Sd 

SUd 

 

This occurs when too much foaming is detected. It is also displayed 
while foaming is removed. When the removal is finished, the normal 
cycle proceeds. (This is one of the normal operations. It is an error 
for preventing non-sensing faults.) 

Check whether the washing machine is level to the floor with respect to the original position of the washing machine prior 
to service. Doing this now will reduce the need for a redo call and customer dissatisfaction.                                                  
✔ Vibrations can shorten the lifetime of the product. 

Silver Care Kit 

(Silver Care 

PCB) Failure.  

7E 

 

Check Silver Care PCB ,Main PCB & Wire-harness 

Mems or Har- 8E 

 

Check MEMS PCB ,Main PCB & Wire-harness 

Location considerations

 

Do not install your washer in areas 
where   water may freeze, since 
your washer will     always maintain 
some water in its water valve, 
pump, and hose areas. This can 
cause     damage the belts, the 
pump, hoses and other compo-
nents. 

Operating temperature 

should be above 60°F/16°C.

 

Содержание WF210ANW/XAA

Страница 1: ... Main PCB input Tests enter Service Mode press the Extra Rinse key until the display shows ln 1 Turn the Dial CCW to Normal Temperature will be dis played in Celsius 2 Turn the Dial CCW to Heavy Duty Temperature will be dis played in Fahrenheit 3 Turn the Dial CCW to Perm Press The door switch status will be displayed CL if Closed OP if Open 4 Turn the Dial CCW to Rinse Spin The door lock Switch s...

Страница 2: ...RY1 ...

Страница 3: ...he volt age change Power On 0Vdc or 3 75Vdc N A Motor Check Test 1 Test 2 Connector CN9 Pin 1 Blue Pin 2 White and Pin 3 Red Power Off 11 5Ω across Pins 1 2 Pins 1 3 Pins 2 3 N A CN1 1 Motor Pwr U Phase Blu 2 Motor Pwr V Phase Wht 3 Motor Pwr W Phase Red CN5 1 Main Valve Blu 2 Hot Valve Red 3 Bleach Valve Pnk 4 Drain Pump Gry 6 Door Lock Wht CN8 Hull Sensor 1 5 vdc Pnk 2 Sensor Signal Red 3 Sensor...

Страница 4: ...here the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign ob ject inside the motor or motor damage The stator might be loose or damag...

Страница 5: ...re If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are ...

Страница 6: ...ons for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the load or remove a few items Press start to continue and complete the wash cycle Foaming Detected SUdS Sd SUd This occurs when too much foaming is detected It is also displayed while...

Страница 7: ...nsumer of proper detergent usage It is normal for some water to remain in Deter gent Drawer after it completes washing Bleach is usually flushed out into the tub at the beginning of the washing Also its compart ment is washed again during the following rinse cycle removing any remnants To unlock the door if washer is stuck in the door locked mode Remove top remove console remove screws for front p...

Отзывы: