Chapter 5 Troubleshooting
Verizon 4G LTE Network Extender for Enterprise User Guide VSR 1.2.6 v1.0
45
© Samsung
Error
Description
Next Steps
FUNCTION_FAIL
GPSR module failure due to a
self-test failure, power failure,
Electronic Frequency Control
(EPC) exceeding normal
operation range, or
OCXO/TCXO failure.
The device is attempting to receive GPS
information.
If the issue persists for more than 12
hours, please ensure that the GPS
antenna is installed in a location near the
window.
If you are not able to receive GPS
information after repositioning the
antenna, you may need to purchase and
install an outdoor GPS antenna. Please
see the GPS outdoor antenna section of
the installation guide.
LOCKING_FAIL
No GPS signal can be
received.
The device is not receiving GPS
information. Please ensure that the GPS
antenna is installed in a location near the
window.
If you are not able to receive GPS
information after repositioning the
antenna, you may need to purchase and
install an external outdoor antenna.
Please see the GPS outdoor antenna
section of the installation guide.
TOD_MSG_MISSED
The TOD message is not
received from the GPSR.
There is a failure preventing your device
from functioning correctly. Please verify if
the GPS antenna is installed properly.
Please contact Verizon Wireless
Customer Care if the issue is not
resolved.
NO_CURRENT_PTP_MASTER
The 1588 clock slave module
fails to get Grand Master
Information.
The device cannot contact the
IEEE1588v2 server. Please ensure that
the IEEE1588v2 server is powered on
and accessible. Check your firewall
settings as defined in this user guide.
NO_PTP_SIGNAL
The SPLL state of 1588 clock
module is abnormal.
There is a failure preventing your device
from functioning correctly. This is a
hardware failure. Please contact Verizon
Wireless Customer Care.
CLOCK_DEV_NOT_INIT
Failure to initialize the 1588
clock module, such as clock
chip configuration and 1588
PTP parameter setup.
There is a failure with your IEEE1588v2
configuration. Please check your settings
and ensure they are correct.
OVER_POWER
RU output power has
exceeded the normal range.
There is a failure preventing your device
from functioning correctly. Please contact
Verizon Wireless Customer Care.
SERVICE_OFF
Service cannot be provided
due to abnormal service
condition.
There is a failure preventing your device
from functioning correctly or your device
has been locked. If the problem persists,
please contact Verizon Wireless
Customer Care.
MME_COMMUNICATION_FAIL
The Network Extender cannot
communicate with backend
servers.
There is a communication failure
preventing your device from functioning
correctly. If the problem persists, please
contact Verizon Wireless Customer Care.