01
On operation
When Eject, Horizontality noise, or
Water-supply is operating, after the finish of the operation.
02
On Full Ice
After removal of ice in the Ice-Tray
Check-Ice Lever ON OFF
No
Items
Method to operate
Remarks
5. TEST function
This is for the case of the Forced-Operation for the purpose of Operation TEST, A/S, and Cleaning
and TEST function operates when TEST S/W implemented with the Ice-Maker itself is pushed for
more than 1.5 second.
1) TEST function does not operate in the case of the Eject operation, Horizontality Noise, Water-
Supply Operation, and Full Ice state. The function operates only in the case of horizontality and
OFF of Lever S/W after cancellation of Full Ice.
2) With the horizontality, by pushing TEST button for more than 1.5 second, Eject operates
immediately regardless of the ice-making condition in the Ice-Tray. So, when the water is not
frozen and TEST function is operated, water will be poured out. After Eject operation and with
Horizontality noise operation, 1 CYCLE of water-supply operates. Therefore, Eject operation,
Horizontality operation, and trouble with water-supply can be checked by TEST button. If TEST
function operates normally, ÒDing-DongÓ sounds and water-supply function operates. So, if there
is no ÒDing-DongÓ sounds, check and repair should be performed.
3) On the finish of water-supply, normal CYCLE of Ice-making Eject Return to Horizontality
Water-supply operates.
<Cases when TEST function does not operate>
6. Function by F-Room DOOR OPEN
This is to minimize the noise by stopping the operation when F-Room DOOR opens.
1) When F-Room Door opens during the operation of Eject or Horizontality noise, operation
stops immediately at that time. With the door closed, normal operation starts again.
2) While water is supplying, normal operation continues, regardless of F-Room DOOR OPEN.
3) So, when TRAY is slanted or is tilted against the level on the check by opening F-Room Door, it
means the stop by F-Room Door OPEN during Horizontality operation. Therefore, close F-Room
Door and allow to return to the Horizontality after water-supply. 30 seconds after F-Room Door is
closed, check the Horizontality and if not, it may be judged to have something wrong.
When terminated by opening of F-Room Door, also TEST function does not operate and operates
after the finish of water supply.
57