(2) When ÒPeepÓ continues to sound,
Whether
Forced-Defrost or Forced-Operation
is selected?
START
Cancellation of Forced-Defrost
or Forced-Operation
Buzzer sounds in spite
of re-POWER ON?
MAIN-PCB is normal
Check of Connector
(CN40), lead TOUCH, insertion
of particles, SHORT
N
N
Y
Y
Information
ÒPeepÓ alarm does not sound except the case of Forced-Operation, Forced-Defrost, and finding
of abnormal things during Self-Diagnosis.
On the finding of abnormal things during Self-Diagnosis, the relevant things can be found on
PANEL-DISPLAY. If PANEL-DISPLAY is normal and ÒPeepÓ continues to sound, it is most
likely that Forced-Operation or Forced-Defrost is selected.
(3) When PANEL-DISPLAY does not turn on,
Connector
insertion of Hinge-Upp Cover
is normal?
START
Re-insertion of Connector,
Repair of Contact trouble
MAIN-PCB
connector (CN50) is normally
inserted?
Re-insertion of
MAIN-PCB connector
Connector
insertion at PANEL-DISPENSER
part is normal?
Re-insertion of Connector,
Repair of contact trouble
Replacement of PANEL-DISPLAY
N
N
Y
Y
N
Y