English
_21
●
in
St
aLL
ation & connection
•
baud Rate Settings
Select the transfer speed of a selected communication protocol.
No.
Baud Rate (BPS)
SW2-#5
SW2-#6
1
2400
ON
ON
2
4800
ON
OFF
3
9600 (Default)
OFF
OFF
4
19200
OFF
ON
•
Communication Method Settings
Select a communication method for the camera.
Function
ON
OFF
SW2-#7
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
•
Communication Response Settings
Select a communication response method for the camera and controller: Response or No
Response.
Function
ON
OFF
SW2-#8
Response Mode Switch
Response
No Response
•
Termination Settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position
SW2-#10
SW2-#11
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
M
`
The default value is shaded in each setting table.
`
To use a third party controller with this product, please contact our After-Sales Service or
Technology Department.