NETWORK PTZ CAMERA
User Manual
21
No.
Baud Rate(BPS)
SW2-#5
SW2-#6
1
2,400
ON
ON
2
4,800
ON
OFF
3
9,600
OFF
OFF
4
19,200
OFF
ON
Function
ON
OFF
SW2- #7
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
Function
ON
OFF
SW2- #8
Response Mode Switch
Response
No Response
Select the transfer speed of a selected communication protocol.
Select a communication method for the camera.
Select a communication response method for the camera and controller: Response or No
Response.
•
Baud Rate Settings
•
Communication Method Settings
•
Communication Response Settings
Camera Input Position
SW2- #10
SW2- #11
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
To prevent the attenuation of communication signals between the camera and controller, the
items at the end of line must be set up with the termination settings.
•
Termination Settings
* This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.