19
4. Troubleshooting
4. Troubleshooting
4-1 Parts checking method
Parts
Photo
Good
No Good
Fuse
0 .1 ~ 1 Ω
100 MΩ exceed
T .C .O
0 .1 ~ 1 Ω
100 MΩ exceed
H .V Trans
1 ~ 9 Ω
100 MΩ exceed
Convection
100 ~ 990 Ω
100 MΩ exceed
Fan Motor
10 ~ 99 Ω
100 MΩ exceed
Grill Heater
10 ~ 99 Ω
100 MΩ exceed