20
4. Troubleshooting
4-2 Error Code Numbering Rule
1.
ERROR CODE NUMBERING RULE is applied to a microwave oven and an oven .(CMO, OTR, Grill, Convection,
Commercial etc .)
2.
All sensors and devices have their own number . ex) Gas Sensor = 1, Temp . Sensor = 2, . . .
3.
Of each device, No .1 and No .2 refer to “Open Error” (not sensed) and “Short Error”, respectively .
4.
This numbering rule has been applied to models to have been developed since January, 1, 2005 . (But, GE or
Customize model are excluded .)
DEVICE
ERROR CASE
0- Others
1- Open
1- Gas Sensor
2- Short
2- Temp . Sensor
•
3- Weight Sensor
•
4- Easy/PH Sensor
•
5- EEPROM
•
•
•
4-3 Error Code List
Gas Sensor
Error
Code
Gas Sensor Error
Case (E-1X)
Solution
Page
E-11
Open
Check Sensor part ,connection of sensor housing and PCB’s
connector .
E-12
Short
E-13
T1 Max Time Error
E-14
Dry Up / No Load
Insert food and restart .
Temp Sensor
Error
Code
Temp. Sensor Error Case (E-2X)
Solution
Page
E-21 Open
Check sensor part and connection of sensor
housing and PCB’s connector .
E-22 Short
E-23 T1 Max Time Error (Preheating not
completed)
Check heater .
E-24 Over temperature error
E-25 In case abnormal temperature is
sensed at Micro Cook
Cool down set and restart .
E-26
In case the temperature is not over
the fixed AD in first 3 minutes after
cooking by heater starts .
Check sensor and heater .
Eeprom Error
Error Code
EEPROM Error Case (E-5X)
Solution
Page
E-51
Open (Sense Failure)
Replace EEPROM and restart .
E-53
Read/Write Error
E-54
Zero not to be set
22 Page
22 Page
23 Page
23 Page
24 Page
29 Page
31 Page
31 Page
34 Page
34 Page