8
SERIAL PORT Setup
4-14
Here comes the initial setup status of the SERIAL PORT SETUP menu.
You can set REMOTE CONTROl, PTZ, or EXTERNAL MODEM in SERIAL PORT
SETUP
- USAGE
Select REMOTE CONTROL, PTZ, or EXTERNAL MODEM.
Each item matches with its own screen.
If you select REMOTE CONTROL, the following screen will pop up.
①
BAUD RATE
Sets up the data transmission speed in RS-232C Communication.
[4,800/9,600/19,200/38,400/57600]
➁
PARITY
Sets up PARITY BIT. [NONE/ODD/EVEN]
➂
DATA BIT
Sets up DATA BIT. [7/8]
➃
STOP BIT
Sets up STOP BIT. [1/2]
➄
UNIT ID
Sets up UNIT ID. [0~99]
DIGITAL IMAGE RECORDER
7
MONITORING Setup
4-13
①
AUTO SEQUENCE
It sets the display time of each channel when you set the sequence in live mode.
[0 sec, 3 sec, 5 sec, 10 sec, 20 sec, 30 sec]
➁
EVENT MONITORING
It sets the function to show the channel where an event(Alarm or Motion) occurs in
full screen. If it is set to ON, the channel where an event(Alarm or Motion) occurs
will be displayed in full screen. [ON/OFF]
➂
MONITORING DURATION
It sets the duration of EVENT MONITORING ON.
[3 sec/5 sec/10 sec/20 sec/30 sec]
MONITORING SETUP
AUTO SEQUENCE
CAMERA 1
3 SEC
CAMERA 2 3 SEC
CAMERA 3 3 SEC
CAMERA 4 3 SEC
EVENT MONITORING OFF
MONITORING DURATION
3 SEC
❷
:MOVE :SELECT MENU:EXIT
SERIAL PORT SETUP
USAGE
REMOTE CONTROL
BAUD RATE
9600
PARITY
NONE
DATA BIT
8
STOP BIT
1
UNIT ID
0
❷
:MOVE :SELECT MENU:EXIT
SERIAL PORT SETUP
USAGE
REMOTE CONTROL
BAUD RATE
9600
PARITY
NONE
DATA BIT
8
STOP BIT
1
UNIT ID
0
❷
:MOVE :SELECT MENU:EXIT
Here comes the initial setup status of the MONITORING SETUP menu.
SHR-4040P/ENG-1 7/24/03 10:28 AM Page 4-13
Содержание SHR-4040P
Страница 1: ......
Страница 5: ......
Страница 12: ......
Страница 14: ......
Страница 21: ......
Страница 31: ......
Страница 34: ......
Страница 35: ......
Страница 39: ......
Страница 40: ......
Страница 42: ......
Страница 45: ......
Страница 46: ......
Страница 49: ......
Страница 52: ......
Страница 61: ......
Страница 66: ......
Страница 72: ......
Страница 73: ......
Страница 75: ......