SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
9-32
9-13. GSM Receiver
CONTINUOUS RX on
RF input : 62CH
Cell power : -50dBm
RX ON
RF input : 62CH.
Cell Power : -50 dBm
Yes
Resolder RFS100
No
C104
≥ -65dBm
Yes
No
L103
≥ -70dBm
Resolder FEM100
Yes
RFT100 pin
11,12,13,14
≥500mV
No
Resolder RFT100 or Check
pins related to RFT100
Yes
Check RFT100
END