SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Flow Chart of Troubleshooting
9-46
9-18. PCS Transmitter
TX ON (0Level)
CONTINUOUS TX ON
RF Input : 698CH
RBW : 100KHz
VBW : 100KHz
SPAN : 10MHz
REF. LVL : 10dBm
ATT. : 10dBm
Check UCP200
No
C186
≥ 2.5V
Yes
R107
≥ 2dBm
No
Resolder RFT100 or Change
RFT100
Yes
PAM100 Pin16
≥ 30dBm
Resolder PAM100 or Change
PAM100
No
Yes
Resolder FEM100 or Change
FEM100
C104
≥25dBm
No
Yes
Check UCP200
END