4. Alignment and Troubleshooting
4.1.8. Tech Mode
In service (tech) mode, the technician can check the machine and perform various test to isolate the cause of a malfunction.
While in Tech mode, the machine still performs all normal operations.
a) Entering the Tech Mode
Press “
Menu > # > 1 > 9 > 3 > 4
” on the control panel.
b) Tech mode menu
Depth 1
Depth 2
Depth 3
Depth 4
Send Level
[9-15]
12
DTMF Level
High [0-15]
Low [0-15]
Pause Time
[1-9]
Dial Mode
Tone,Pulse
Tone
Modem Speed
33.6, 28.8, 14.4, 12.0, 9.6, 4.8
33.6
Error Rate
5%, 10%
10%
Clear All Mem.
Toner Low Level
[1:30]:10
Platen Scan
ADF Scan
Transfer Roller
Fuser
Pickup Roller
Retard Roller
Forward Roller
Clear Count
Enter Password [????]
Feed Roller
Off*
Engine Footer
On
On
Dial Tone
Off
On
Data Setup
Caller ID
Off
Switch Test
Test Param Set
Modem Test
Dram Test
Rom Test
Shading Test
Machine Test
Scan Aging
4-21