12_
connection & installation
CAMERA WIRING INTERFACE BOARD
For the camera wiring, please refer to the picture below.
(When using coaxial communication, a separate control signal connection is not required.)
• RS485 Communications
• RS422 Communications
Camera
Camera
RX+
RX-
RX+
RX-
TX+
TX-
TXD+
TXD-
TXD+
TXD-
RXD+
RXD-
Controller
or DVR
Controller
or DVR
Control Signal Connection
The max capacity of the Alarm OUT/AUX OUT ports are 30VDC/2A, 125VAC/0.5A, and 250VAC/0.25A, respectively.
Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a short circuit and fi re,
damaging the camera.
Never use installation base for previous models (for SCP-2370/3370 and SPU-3750T/3700 models) with this product, it is not
compatible with this product. Otherwise, applying power may lead to short circuit and result in fi re or damage to the product.
M
7*%&0
*/
*/
'(
39
39
*/
(/%
*/
39 39 59 59 (/%$0./0
%
+
IN5
IN6
IN7
IN8
GND
2.COM
2.NO
2.NC
2.COM
2.NO
2.NC
1.NC
1.NO
1.COM
GND
IN4
IN3
IN4
3.COM 3.NO
Communications and Alarm/AUX
Refer to the below Control
Signal Connection chart
Power Supply
AC24V 2.5A
Alarm/AUX
Alarm/
AUX Output 1
Alarm Input
1~4
Power Input
Alarm/AUX
Output 3
Ground
Alarm Input
5~8
Alarm/
AUX Output 2
connection & installation