16_ Connection
Connection
½
RS-485 Communication establishment initial value.
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
When making a control system to control the camera, please use to the protocol SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, AD, GE.
When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer skin inside the
RS-485 CONTROL TERMINAL.
USING COAXIAL COMMUNICATIONS
CAMERA
DVR
CONTROLLER
SET
MENU/ENTER
OSD KEY
UP
UP KEY
JOYSTICK UP
DOWN
DOWN KEY
JOYSTICK DOWN
LEFT
LEFT KEY
JOYSTICK LEFT
RIGHT
RIGHT KEY
JOYSTICK RIGHT
• Coaxial Communications System
• OSD Control method
• If you set the sensitivity level of the sub menu item (of COAX) to “Low”, you have to
press the MENU/ENTER (OSD KEY) button twice in a row to access the OSD menu.
(To prevent an error by noise from the DVR)
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
(TRX+)
(-) CONNECTION TERMINAL
(TRX-)
y
Motion detection signals are output through this terminal.
y
Used for earth-grounding.
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX)
SERIAL PORT OF THE PC(COM1)
SERIAL CABLE
RS-485 CONVERTER
RS-485 CONTROL CABLE
MD-OUT:
GND: