Thermal Night Vision Camera
User Guide
28
Thermal Night Vision Camera
User Guide
29
Item
SCB-9050
SCB-9051
Detector
320(H)x240(H) Uncooled VOX Microbolometer
Sensor Pitch
23.5μm × 23.5μm
Measured wavelength range
8 ~ 14um
Video ratio (Sensor)
NTSC : 30 fps / PAL : 25 fps
Video output
CVBS : 1.0VP-P, 75Ω composite
Lens
F1.4, f=14mm
F1.4, f=50mm
Focus Range
0.5m ~ ∞
(Factory default : 3m~∞,Pan Focus )
27m ~ ∞, Pan Focus
Viewing angle(H x V)
30˚ x 22.8˚
9.2˚x 6.9˚
IFOV (Instantaneous field of view)
1.68mrad
0.47 mrad
Digital zoom
2x ~ 4x
Noise reduction function
3D-DNR (4step : Low/Midium/High/Off)
Polarity function
BW(Black & White) / WB(White & Black)
Detecting temperature
Auto / Manual(2step)
Low(-40~150), High(0~540)
Communications specifications
RS-485
Protocol
Samsung Techwin, Pelco-D
Dustproof/waterproof
protection rating
IP66
Operating temperature
-30
℃
~ 55
℃
Storage temperature
-40
℃
~ 70
℃
Input voltage
24V AC, 50/60Hz
Electricity consumption
10.5W (Operating Heater 22W)
Outer diameter size
104(W)×123(H)×352(D) mm
104(W)×123(H)×367(D) mm
Weight (Camera)
2.2Kg
Image Processing
AGC & DDE
NETD
80mK
Low range : 80mK,
High range : 300mK
* Although the infrared sensor has been built using high-precision technology, please understand that there
may be times when pixels may be lost, or remain stuck/flashing. Also, be aware that continuously monitoring
a high temperature object beyond a certain period of time may produce an afterimage.
* In cases where the product installation site experiences a sudden change in temperature (dropping by 15°C
or more), the camera’s focus will become blurred with regards to subjects located within three meters.
Specifications
MAIN SETUP
1. BRIGHTNESS
AUTO
2. CONTRAST
MANUAL
3. RANGE
AUTO
4. NUC
5. NUC MOOE
INTERVAL
6. IMAGE ADJ
7. SPECIAL
8. SAVE
9. EXIT
Press the SET button while the cursor is aligned with “9. EXIT” to close the MAIN SETUP menu.
①
After switching BRIGHTNESS and/or CONTRAST to MANUAL and saving your changes, images
may not be displayed the next time you restart the device. To render images in such a case, set
BRIGHTNESS and/or CONTRAST to “AUTO” or readjust the MANUAL setting.
②
If you save after changing the RS485 communications CAMERA ID, the ID will then be set/stored.
If the CAMERA ID was set incorrectly, exit without saving.
EXIT (Close Menu)
• Do not disengage the power while settings are being saved.
Notes
Operating the Camera