Thermal Night Vision Camera
User Guide
12
Thermal Night Vision Camera
User Guide
13
Inputting Power
Startup
Connect the video output terminal on the rear of this product to the monitor.
■
Connecting the Monitor
IR camera
Intermediate video receiver
End equipment
* Deviations may occur depending on the type of power cable shown in the chart above, and on the
wiring manufacturer.
When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size (AWG)
#24(0.22
2
)
#22(0.33
2
)
#20(0.52
2
)
#18(0.83
2
)
Resistance (Ω/m)
0.078
0.050
0.030
0.018
Voltage Drop (V/m)
0.028
0.018
0.011
0.006
• This device is not fitted with a power switch. The device
must be provided with power to turn it
• After checking the label on the cable on the right side of
the camera, connect the output cable of the provided
adapter.
• Refer to the owner’s manual for each device. Connection methods employed may differ
depending on the monitors and peripheral devices used.
• Before connecting devices, ensure their power is turned off.
• Adjust the 75Ω/Hi-Z conversion switch for each device based on the following
illustration. Select “Hi-Z” for intermediate video receivers and “75Ω” for end equipment.
Calibration (NUC MODE)
Monitor/Communications Connection
Installing the Camera
1. Remove the lens cap.
2. Engage the power. (Use the adapter provided with this product.)
3. The rated input voltage for this product is AC 24 V, 50/60 Hz.
1. The START screen will appear after the power has been turned on.
2. After completion of initialization, thermal images will be displayed. (approx. ten seconds
after engaging the power)
This device will perform a calibration necessary for imaging (NUC) after the internal shutter
closes.
During NUC, the screen will freeze momentarily. Please note that this is not a malfunction.
The sensor will not operate properly immediately after the power is turned on, or when switching
between HIGH and LOW ranges. As a result, thermal images will not display consistently for several
seconds. Menu controls can be used to save values to be applied at subsequent start-up of the
SCB-9050/9051. (If values are not saved, then the last saved settings will be applied.)
• A 22-18 gauge power wire is recommended for this camera.
• Voltage reinforcement will occur based on the length of the power wire. If the adapter
output wire is too long, camera performance may suffer.
Notes
IR camera
Monitor