DEVELOPMENT TOOLS
S3F80P5_UM_ REV1.00
Table 19-1. Setting of the Jumper in TB80PB
JP#
Description
1-2 Connection
2-3 Connection
Default
Setting
S1
Target board power source
Use JP7(VCC)
NOT connected
Join 1-2
JP1
Target board mode selection
H: Main-Mode
L: EVA-Mode
Join 2-3
JP2
Operation Mode
H: User Mode
L: Test-Mode
Join 1-2
JP3
MDS version
SMDS2
SMDS2+,SK-1200,OPENIce I-500 Join 2-3
JP4
To
User_Vcc
Target system is supplied V
DD
Target system is supplied
V
DD
from user system.
Target system is not supplied V
DD
from user system.
ON setting
JP5
Board peripheral power
connection
Board peripheral power connection
Connect
JP6
When supplied 5V in target board,
generation of 3.3V using
regulator.
In case of selection 3.3V of
Emulator (Not use 3.3V
regulator)
In case of selection 5V of
Emulator (Use 3.3V
Regulator)
Join 2-3
JP7,JP9
POWER connector
JP7: VCC JP9:GND
-
JP8
80PBX V
DD
power connection
80PB V
DD
power connection
Connect
JP10
Clock source selection
When using the internal clock source which is generated from
Emulator, join connector 2-3 and 4-5 pin. If user wants to use
the external clock source like a crystal, user should change the
jumper setting from 1-2 to 5-6 and connect Y1 to an external
clock source.
Emulator
2-3
4-5
JP11,12
NOT used for TB80PB
-
NOT
connected
SW1
Generation low active reset signal
to S3F80PB EVA-chip
Push switch
-
SW2
Smart option at address 3EH
Dip switch for smart option. This 1byte is mapped address
3EH for special function. Refer to the page 2-3.
SW3
Smart option at address 3FH
Dip switch for smart option. This 1byte is mapped address
3FH for special function. Refer to the page 2-3.
Y1
External clock source
Connecting points for external clock source
J3
Header for flash serial
programming signals
To program an internal flash, connect the signals with flash
writer tool.
J3
To
User_Vcc
Target System is supplied V
DD
Target Board is not supplied
V
DD
from user System.
Target Board is supplied V
DD
from user System.
Join 2-3
– nRESET
LED
This LED is OFF when the Reset switch is ON.
– IDLE
LED
This is LED is ON when the evaluation chip (S3E80PB) is in idle mode.
19-4
Содержание S3F80P5X
Страница 10: ......
Страница 14: ......
Страница 19: ...S3F80P5_UM_ REV1 00 PRODUCT OVERVIEW BLOCK DIAGRAM 24 PIN PACKAGE Figure 1 1 Block Diagram 24 pin 1 3 ...
Страница 48: ...ADDRESS SPACE S3F80P5_UM_ REV1 00 NOTES 2 22 ...
Страница 122: ...INTERRUPT STRUCTURE S3F80P5_UM_ REV1 00 NOTES 5 18 ...
Страница 210: ...INSTRUCTION SET S3F80P5_UM_ REV1 00 NOTES 6 88 ...
Страница 216: ...CLOCK AND POWER CIRCUITS S3F80P5_UM_ REV1 00 NOTES 7 6 ...
Страница 266: ...COUNTER A S3F80P5_UM_ REV1 00 NOTES 12 8 ...
Страница 290: ...EMBEDDED FLASH MEMORY INTERFACE S3F80P5_UM_ REV1 00 NOTES 14 18 ...
Страница 316: ...S3F80P5_UM_ REV1 00 ELECTRICAL DATA STOP LED This LED is ON when the evaluation chip S3E80PB is in stop mode 19 5 ...