![Samsung S3F80P5X Скачать руководство пользователя страница 220](http://html.mh-extra.com/html/samsung/s3f80p5x/s3f80p5x_user-manual_349401220.webp)
RESET
S3F80P5_UM_
REV1.00
RESET MECHANISM
The interlocking work of reset pin and LVD circuit supplies two operating modes: back-up mode input, and system
reset input. Back-up mode input automatically creates a chip stop state when the voltage at V
DD
is lower than
V
LVD
. When the LVD circuit detects rising edge of V
DD
on the point V
LVD
, the reset pulse generator makes a reset
pulse, and system reset occurs. When the operating mode is in STOP mode, the LVD circuit is disabled to reduce
the current consumption under 5uA (at V
DD
= 3.6 V). Therefore, although the voltage at V
DD
is lower than V
LVD
,
the chip doesn’t go into back-up mode when the operating state is in stop mode.
WATCH DOG TIMER RESET
The watchdog timer that can recover to normal operation from abnormal function is built in S3F80P5. Watchdog
timer generates a system reset signal, if Basic Timer Counter (BTCNT) isn’t cleared within a specific time by
program. For more understanding of the watchdog timer function, please see the chapter 10, Basic Timer and
Timer0.
LVD RESET
The Low Voltage Detect Circuit (LVD) is built on the S3F80P5 product to generate a system reset. LVD is
disabled in stop mode. When the voltage at V
DD
is falling down and passing V
LVD
, the chip goes into back-up
mode at the moment “
V
DD
= V
LVD
”.
As the voltage at V
DD
is rising up, the reset pulse is occurred at the moment
“V
DD
≥
V
LVD
“.
STOP Instruction
Reset
LVD
STOPCON
(note 2)
(note 3)
Figure 8-3. RESET Block Diagram by LVD for the S3F80P5 in Stop Mode
NOTES
1. LVD is disabled in stop mode. LVD always operates in any other operation modes.
2. CPU can enter stop mode by setting STOPCON (Stop Control Register) into 0A5H before execution
STOP instruction.
3. This signal is output relating to STOP mode. If STOPCON has 0A5H, and STOP instruction is
executed, that output signal makes S3F80P5 enter STOP mode. So that is one of two statuses;
one is STOP mode, the other is not STOP mode.
8-4
Содержание S3F80P5X
Страница 10: ......
Страница 14: ......
Страница 19: ...S3F80P5_UM_ REV1 00 PRODUCT OVERVIEW BLOCK DIAGRAM 24 PIN PACKAGE Figure 1 1 Block Diagram 24 pin 1 3 ...
Страница 48: ...ADDRESS SPACE S3F80P5_UM_ REV1 00 NOTES 2 22 ...
Страница 122: ...INTERRUPT STRUCTURE S3F80P5_UM_ REV1 00 NOTES 5 18 ...
Страница 210: ...INSTRUCTION SET S3F80P5_UM_ REV1 00 NOTES 6 88 ...
Страница 216: ...CLOCK AND POWER CIRCUITS S3F80P5_UM_ REV1 00 NOTES 7 6 ...
Страница 266: ...COUNTER A S3F80P5_UM_ REV1 00 NOTES 12 8 ...
Страница 290: ...EMBEDDED FLASH MEMORY INTERFACE S3F80P5_UM_ REV1 00 NOTES 14 18 ...
Страница 316: ...S3F80P5_UM_ REV1 00 ELECTRICAL DATA STOP LED This LED is ON when the evaluation chip S3E80PB is in stop mode 19 5 ...
Страница 321: ...DEVELOPMENT TOOLS S3F80P5_UM_ REV1 00 NOTES 19 10 ...