Installing the Refrigerant Pipe Work (Continued)
Select the first Y-joint depending on the outdoor unit capacity.
Select the other Y-joints depending on the total capacity of attached indoor
units below the selected joint individually.
Selecting the Y-joint
Selecting the first Y-joint
Outdoor capacity (HP)
Y-joint model
4, 5
MXJ-YA1509A
6
MXJ-YA2212A
The other Y-joint
Total capacity of
attached indoor units
below this Y-joint (kW)
Y-joint model
X < 22.4
MXJ-YA1509A
Selecting additional refrigerant charge
Basic charge
The basic amount of refrigerant for outdoor unit charged in factory is 5.5kg,
and the amount for pipe is 1.2kg.
Estimate after EEV kit (Using EEV kit)
Additional Charge (kg) = {(L
1
x0.01) + (L
2
x0.01)} - Basic charge for pipe
L1:Total length of liquid pipe Ø 6.35(m)
L2:Total length of liquid pipe Ø 9.52(m)
Do not charge additional refrigerant if the estimate is less
than 1.2kg.
Additional Charge (kg) = {(L
1
x0.02) + (L
2
x0.06)} - Basic charge for pipe
L1:Total length of liquid pipe Ø 6.35(m)
L2:Total length of liquid pipe Ø 9.52(m)
Depends on the total length of the liquid side pipe.
RVXMHF04E0A_E_IM_24820.indd 20