75
Ⅵ. TROUBLESHOOTING
F1
If the Door switch is transformed
or badness, the current comes
down from 200mA to 0mA after
turning on the camera.
Door Switch
BATTERY L/W
Check the connection of
JOG FPCB and MAIN PCB
If the F1 (FUSE) is damaged, there is
no the consumption of current(0mA)
after turning on the camera.
Q5
If the Q5 is damaged, the
camera can't be turned on.