© SAMSUNG Electronics Co., Ltd.
17
Failure 2
When Ring is not terminated.
Troubleshooting 2
No
Is HOS(Hook Off Sensing) output?
Yes
Replace TMC(U51)
No
Is the ring
supplying voltage higher
than 40 Vrms?
Check if ring supplying voltages at the
TIP and RING are higher than 40 Vrms
Yes
Request to repair the trunk line
- Check the ring path
- Consisting of two Zener diodes
END