Step 8. Convert to lp gas (optional)
All new gas ranges are shipped from the
factory set up to use natural gas. Any
Samsung gas range can be converted to use
LP gas. Refer to page 97 in the User Manual
to contact a qualified service technician.
The conversion process should only be
performed by a qualified LP gas installer.
Conversion instructions and LP orifices will
be supplied with the LP conversion kit. The
conversion to LP requires all burner orifices
to be changed (5 surface burners).
In addition, the nozzle on the gas pressure
regulator needs to be reversed. All replaced
orifices must be left with the consumer,
including the instructions and retrofit sizes
and orifice indication.
Checking the flame quality all burner after
converting to lp gas.
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (LP Gas [Propane] 10 in WCP)
Burner
Location
BTU Rate
Orifice Size
[mm]
RF
16500
In: 0.46/
Out: 0.83 (2 pcs)
LF
11500
1.04
RR
4000
0.62
LR
7500
0.83
CTR
7500
0.83
BAKE
15000
1.15
BROIL
14500
1.12
BURNER ORIFICE SIZES AND OUTPUT
RATINGS (Natural Gas 5 in WCP)
Burner
location
BTU Rate
Orifice size
[mm]
RF
22000
In: 0.85/
Out: 1.36 (2 pcs)
LF
15000
1.78
RR
5000
1.01
LR
9500
1.40
CTR
9500
1.38
Содержание NY58J9850WS
Страница 1: ...Dual Fuel Range Installation manual NY58J9850WS ...
Страница 46: ...Memo ...
Страница 47: ...Memo ...
Страница 49: ...Estufa de combustible dual Manual de instalación NY58J9850WS ...
Страница 94: ...Notas ...
Страница 95: ...Notas ...
Страница 97: ...Cuisinière mixte Manuel d installation NY58J9850WS ...
Страница 142: ...Notes ...
Страница 143: ...Notes ...