Installation instructions
Ins
tallation ins
truc
tions
Installing a 3-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and
voltage to make the connection. Connect wires according to Step 4 depending on the
number of wires.
• Wire used, location and enclosure of splices, etc., must conform to good wiring practices and
local codes.
Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and
voltage to make the connection. Connect wires according to this Step 4 depending on the
number of wires.
• Wire used, location and enclosure of splices, etc., must conform to good wiring practices and
local codes.
1.
Loosen the 3 lower terminal screws from
the terminal block.
2.
Insert the center bare wire (white/neutral)
tip through the bottom center terminal
block opening. On certain models, the
wire will need to be inserted through the
ground strap opening and then into the
bottom center block opening.
3.
Insert the two side bare wire tips into the
lower left and the lower right terminal
block openings.
4.
Tighten the screws until the wire is firmly
secured (35 to 50 inch-lbs.). Do not over-
tighten the screws since it could damage
the wires.
5.
Go to
step 6
on page 34 and proceed with
the installation.
White
Black
Red
Ground
strap
Neutral
terminal
Wire tips
Red
White
Black
Содержание NY58J9850WS
Страница 1: ...Dual Fuel Range Installation manual NY58J9850WS ...
Страница 46: ...Memo ...
Страница 47: ...Memo ...
Страница 49: ...Estufa de combustible dual Manual de instalación NY58J9850WS ...
Страница 94: ...Notas ...
Страница 95: ...Notas ...
Страница 97: ...Cuisinière mixte Manuel d installation NY58J9850WS ...
Страница 142: ...Notes ...
Страница 143: ...Notes ...